Technical Section WAGO

| Kategorie: Leták / Datasheet Firemní tiskovina  | Tento dokument chci!

Vydal: WAGO Elektro spol. s r.o.

Strana 27 z 44

Jak získat tento dokument?






Poznámky redaktora
6) 115 170 190 240 1 (42.4 g Values parentheses apply connectors with assigned ampere ratings.82) 19 16 (1. Test performed per: UL 1059 486 (Splicing wire connectors) UL 486 (Equipment wiring terminals) Test performed with maximum rated cross section Test performed with maximum rated cross section Test current: 150% maximum rated current Test current: Increased test current per UL 486 Table 6 UL 486 Table 4 84 cycles of: 1/2 1/2 OFF 500 cycles of: OFF 1 1/2 1/2 OFF (from 4/0 AWG 400 kcmil per 486 E) The temperature rise measured after the first and the 84th cycle.05) 3. The temperature rise must not exceed 5°C (41°F) after the 84th cycle, compared the temperature measured after the first cycle.4) 130 195 220 275 1/0 (53.3) 105 131 105 4 (21.7) 100 145 165 205 2 (33.2) 125 140 175 3 (26. e Values for AWG and larger conductors are approximately 140% the static heating test currents. d Values are approximately 112% the static heating test currents.52) 16 18 (0.2. f See Section 9.5 3.32) 12 20 (0.2, 8. . The temperature rises the terminal blocks and control conduc- tors are measured and recorded after: 25, 50, 75, 100, 125, 175, 225, 275, 350, 425 and 500 cycles.5 5.4) 175 265 300 370 3/0 (85.3) [25] [28] [40] 38 10 (5.4) 100 80 6 (13. c Values are for 75°C (167°F) single conductors free air ampacities, National Electric Code, ANSI/NFPA 70.2 (UL 486 E) b Values are for 75°C (167°F), not more than conductors raceway cable ampacities, National Electric Code, ANSI/NFPA 70. The temperature rise must not exceed 125°C (257°F) and the sta- bility factor “S” must not exceed ±10.5 6 24 (0.wago.5) 150 230 255 320 2/0 (67.com WAGO Rail-Mount Terminal Block Systems Technical Information Tests and Testing Procedures per Standards (continued) UL Specifications Underwriters Laboratories, USA (continued) • Heat Cycling Test per 1059, 486 E Conductor Size Test Current for Copper Conductors A UL 486 Table 486 Table 6 AWG or kcmil Assigned Maximum Ampere Ratingb Static Heatinga,c,g Heat Cycling Temperature Ratinga Static Heating Heat Cycling (mm²) 75°C (167°F)d,g 90°C (194°F)e,g 30 (0.3) [40] [45] [60] 56 8 (8.1) [20] [22] [27] 33 12 (3.13) 5.2) 8 22 (0.26 www.08) 3.5 3.5 4 26 (0.3) 20 14 (2.2 and 9.5 28 (0.0) 200 310 345 435 4/0 (107) 230 360 405 505 250 (127) 255 405 445 565 300 (152) 285 445 500 625 a See Section 7