Lightning protection guide by OBO

| Kategorie: Katalog  |

Last revision 2020

Vydal: OBO BETTERMANN s. r. o. Autor: OBO BETTERMANN

Strana 145 z 288

Jak získat tento dokument?






Poznámky redaktora
Thanks the patented design, the equipotential bus- bar can used system according IEC 60079- 14 and IEC/EN 62305-3 the zones 1/21 and Ex zones 2/22. According TRBS 2152 Part and IEC/EN 62305-3, the arresting paths the lightning must created in such way that heating ignitable sparks spray sparks cannot become the ignition source poten- tially explosive atmosphere.g. The PAS equipotential busbar for potentially ex- plosive areas possesses the following properties: • Suitable for all explosion groups and use Ex zones 1/21 and 2/22 • Free ignition sparks with lightning current up to kA • Tested according Class for high loads • Screws protected against self-loosening • Made from corrosion-resistant material (stainless steel) • Manufacturer and article labelling permanently at- tached Strip Earthing clamp for Zone 1/21 and 2/22 BES TBS Blitzschutz-Leitfaden 2018 / en / 2020/01/10 14:42:40 14:42:40 (LLExport_02613) / 2020/01/10 14:42:54 14:42:54 145 Chapter The external lightning protection system . Areas application could include: • Chemicals industry • Paint shops • Oil and gas industry • Fuel depots • Gas pressure regulation and measurement systems (GDRM systems) • Liquefied gas storage containers • Balance pits and large outdoor filling systems • Filling and emptying points (e.3 Solutions Equipotential bonding systems Systems potentially explosive areas require equipo- tential bonding according IEC 60079-14.3. Big-Bag sacking, balances, sack handover) Supplementary Sheet (IEC 62305-3) requires that connections lightning protection systems poten- tially explosive areas are created such way that no ignitable sparks are created when the lightning cur- rent passes through. All the bodies electrically conductive parts must con- nected the equipotential bonding system. Secure equipotential bonding connections against self-loosen- ing according IEC 60079-14 and the Technical Rules for Operating Safety (TRBS) 2152 Part 3. Equipotential busbar for zone 1/21 and 2/22 PAS The PAS equipotential busbar (equipotential bus- bar for potentially explosive areas) used for light- ning protection equipotential bonding according to IEC 62305-3 and protective/functional equipotential bonding according DIN VDE 0100 Part 410/540. OBO can offer innovative solutions for this. The lack ignition sparks explosive atmosphere has been tested according IEC/EN 62561-1 ac- cording the most demanding explosion group, IIC, with potentially explosive gas mixture and lightning current kA. the PAS equipotential busbar does not pos- sess its own potential source ignition, does not come under the European Directive 2014/34/EU. The PAS equipotential busbar tested according to IEC/EN 62561-1 Class for high loads and is suitable for indoor and outdoor applications. The PAS represents the current state of the art for equipotential busbars areas.TBS Blitzschutz-Leitfaden 2018 / en / 2020/01/10 14:42:40 14:42:40 (LLExport_02613) / 2020/01/10 14:42:54 14:42:54 2. can thus used all ex- plosion groups, even the explosion groups IIB and IIA