Poznámky redaktora
7. The files are
stored the standard Comma Separated Values (CSV)
format that can imported applications such as
Microsoft Excel for processing.
16 3AU A0000041481 REV 3.
If ergency situations faults occur, the internal
w server the SREA-01 provides easy-to-use
user interface for accessing the drives. Furthermore,
with qualified service people site vital be
able monitor the drive remotely. A
maximum drives can connected single
SREA-01 module, although additional RS-485
converter needed for each drive several drives are
connected their panel port interfaces.2009
.
In addition providing data logging functionality, the
SREA-01 also has internal Modbus TCP gateway,
providing standard interface that can used by
SCADA (Supervisory Control And Data Acquisition)
applications display drive information real-time. The event
conditions and messages can configured the user
to make them suitable for num ber applications.
The SREA-01 connected the panel port, or
alternatively the Modbus interface, drive. The event and alarm messages
can sent SMS messages e-mail.Remote monitoring and diagnostic tools
SREA-01 enables remote access
With drives increasingly being installed remote
locations, operational data needs acquired
from the process for sending central location for
process monitoring and further analysis.
Connect maximum drives an
Ethernet GPRS network
In addition standard Ethernet port, the SREA-01 is
equipped with additional serial port for connecting
to standard GSM/GPRS odem for Internet
connectivity isolated places.
The collected data logs can sent e-mail FTP,
either local area network the Internet.
A BB’s SREA-01 Ethernet adapter performs all these
rem ote access tasks. The
sending interval can also configured the user,
with logs being sent, for exam ple, every hour once
a week.
Receive alarms and access the drive
remotely
The SREA-01 unit can used monitor the
drive for abnormal situations, such too high
process temperatures, and send alarm essages to
m aintenance personnel. Designed optional remote
interface module for the drives, the SREA-01 can
send process data, data logs and event messages
independently, without PLC dedicated on
site computer, and has internal server for
configuration and drive access.
Collect data logs and integrate drive data
in SCADA applications
For collecting data from the drive for further analysis,
the SREA-01 has fully configurable data logger that
can store values from the drives file, with sample
intervals from ten seconds one hour. Travel sites
can often avoided using regular browser
to view and change the drive parameters, monitor the
status all connected drives and brow the fault
history the installation. The modem connection
can used for sending e-mail SMS messages,
uploading data files FTP accessing the Web
pages the module