3 kV, 4.0 6.Data sheet ACS 1000, ACS 1000i Inverter type Three-level Voltage Source Inverter (VSI) with fast-switching power semiconductors - Integrated Gate Commutated Thyristors (IGCTs), without parallel series connected devices Motors Induction motors; ACS 1000: 315 2000 air cooled 1800 5000 water cooled ACS 1000i: 315 2000 air cooled Standards All common standards including (IEC), CE, UL, cUL Input ACS 1000: Any medium voltage level, Hz, can be applied the appropriate primary side of the converter input transformer.96 Overload capacity Standard: Normal use, 10% short term over­ load capacity allowed for one minute every minutes Optional: For higher overload capacity contact ABB Ambient temperature +1° 40° (higher with derating) 34° 104° (higher with derating) Enclosure classes ACS 1000 Air cooled: IP21, IP22, IP31, IP32, IP42 Water cooled: IP31, IP54 ACS 1000i IP21, IP42 IndustrialIT Compatible (Level 1) Protective functions Overcurrent, short circuit, earth fault, input phase loss, output phase loss, overvoltage, undervoltage, over-temperature, motor over­ load, motor underload, motor stall protection, and many others Optional • Redundant cooling fan (air-cooled and water- cooled ACS 1000) and pump (water-cooled ACS 1000) for enhanced reliability • Braking chopper for effective motor braking and short deceleration times • Bi-directional bypass (start-up bypass for synchronous transfer motors to the line and taking back machine from line to VSD operation) Optional control connections Extensive range additional I/O features available Control interface (optional) All common fieldbuses including Profibus, Modbus, Allen-Bradley DeviceNet, Ethernet, ABB Advant Fieldbus AF100 (others request) 12 ACS 1000, ACS 1000i ABB .97 Total: 0. Alternatively the drive can be equipped with back-up batteries. Output frequency 0 ±66 (±82.6 kV, 50 Hz, request kV Variation (ACS 1000, ACS 1000i): ±10 nominal voltage, down to -25 safe operation with derated output Auxiliary voltage 400 VAC ±10 50/60 Hz 480 VAC ±10 Hz 575 VAC ±10 Hz, phase UPS (Uninterruptible Power Supply) If available, UPS can connected for control power supply, 110 240 VAC ±10 %, single phase. ACS 1000i: Voltage range: 4.5 optional) Output voltage Standard: Sinusoidal, 2.16 7.16 kV Optional: Higher voltages with step-up transformer Input bridge aCs 1000 Standard: 12-pulse Optional: 24-pulse ACS 1000i Standard: 24-pulse Efficiency converter ACS 1000 typically % ACS 1000i typically (incl. integrated transfomer) Input power factor Fundamental: 0.2 kV, Hz/6.3 kV, 0 3.0/4