Petersenova cívka s regulátorem REG-DP

| Kategorie: Leták / Datasheet  |

Operating Instructions for the Petersen-Coil Regulator

Vydal: EBERLE Controls GmbH

Strana 138 z 272

Jak získat tento dokument?






Poznámky redaktora
12 End_H/L Message: The regulator recognized the end position 'Higher' OR 'Lower'. 17 Block Message: The regulator operating mode AUTO but blocked by an event. 14 Tuned Message tuned: The search process was completed successfully.Page 138 Detailed description REG-DP/ REG-DPA parameters We take care it. 15 Tnd_nc Message tuned not compensated: The regulator took the precon- ditions into account and adjusted the coil the best possible value. 6 Une Uerd Message: The zero sequence voltage bigger than the set earth fault threshold. 4 Status Message: Regulator status: Summary message all self-test functions, such as 0 RAM/ROM 0 EEPROM 0 Battery empty 0 Watchdog 5 <AUTO> Message: The regulator operating mode AUTO. 16 Umax_nc Tuned not compensated message because the set Umax threshold is preventing tuning. 1 PROG The relay allocated the background program. 2 Motor_H Command the P-coil: Adjust direction 'Higher'. The desired compensation value could not reached be- cause outside the P-coil's adjustment range. The signal is OR-gate for the position command 'Motor Higher', 'Motor Lower' and the input 'Mot_Run'. 10 End_H Message: The regulator recognized the end position 'Higher'. 3 Motor_L Command the P-coil: Adjust direction 'Lower'. This message generated after the de- fined delay time. It's put there by EspRelPV. 7 Une Uerd_td Message delayed: The zero sequence voltage bigger than the set earth fault threshold Uerd. Name Function 0 OFF: Relay not allocated. Table 7-2: Set-up options for binary outputs and LEDs No. 8 Une Umax Message: The zero sequence voltage bigger than the set maxi- mum earth fault threshold Umax. This the OR-gate from the two previous messages. 18 Homepos1 Message: The regulator has reached the end position (standby position last tuning position). The desired compensation value was set successfully. 11 End_L Message: The regulator recognized the end position 'Lower'. 9 Une Umin Message: The regulator searched the whole adjustment range and did not find zero sequence voltage bigger than the set minimum zero sequence voltage. '0' '1' output based the inversion. 13 Mot_Run Message: The regulator recognized P-coil adjustment. This standby position moved toward after: 0 Unsuccessful search because Uen Umin the whole adjust- ment range