Petersenova cívka s regulátorem REG-DP

| Kategorie: Leták / Datasheet  |

Operating Instructions for the Petersen-Coil Regulator

Vydal: EBERLE Controls GmbH

Strana 134 z 272

Jak získat tento dokument?






Poznámky redaktora
20 Search The signal's rising edge triggers search. 21 R_start The signal's rising edge triggers the resistor's connection for the residual current increase. search started after the block has been removed. (for more information see Chapter 7. No. Parallel regulation activated 30 Fix coil Static signal regulator: fixed coil connected., the ex- ternal temperature monitoring the resistor 26 Imp_CI_on REG-DP/ REG-DPA uses impulse switch current injection. This especially impacts the calculation the relative compensation 31 Quit error Acknowledge error messages 32 EarthF_Corr1 Static signal regulator: The P-coil corrected set value when an earth fault occurs.3.Page 134 Detailed description REG-DP/ REG-DPA parameters We take care it.2.g. search started after the block has been removed. Only when used combination with current injection (CI feature) 28 Reserved Reserved for future use 29 Coupling Static signal regulator: The busbar was connected through transvers or lateral coupling. used when the CORR_TAB feature selected 33 EarthF_Corr 2 34 EarthF_Corr 3 35 EarthF_Corr 4 36 R_enabled Releases the resistor control from self-blocking. 19 S:BlockT Static signal regulator: Block the regulator because the P-coil's tempera- ture too high. Only when used combination with current injection (CI feature) 27 Imp_CI_off REG-DP/ REG-DPA uses impulse switch off current injection. Name Function 10 E:Error P-coil regulator: Currently works only BOF41: E:Error forwarded no function defined! 11 Imp:Local Impulse regulator: Regulator should switch 'Local' mode 12 Imp:Remote Impulse regulator: Regulator should switch 'Remote' mode 13 Imp:L/R Impulse regulator: Regulator should switch 'Local/Remote' mode 14 Stat:R static signal switches the regulator Remote 15 Imp:AUTO Impulse regulator: Regulator should switch 'AUTO' mode 16 Imp:MAN Impulse regulator: Regulator should switch 'MAN' mode This switch is also used acknowledge error conditions 17 Imp:A/M Impulse regulator: Regulator should switch 'AUTO/MAN' mode 18 S:Block Static signal regulator: Block the regulator.3) 22 R_auto_on Impulse regulator: Activate resistor control 23 R_auto_off Impulse regulator: Deactivate resistor control 24 R_auto_onoff Impulse regulator: Switch between activation/deactivation the resis- tor control 25 R_block The resistor’s connection blocked external signal, e. The resistor control is 'primed' for the next earth fault 37 CI_block The REG-DP/ REG-DPA blocks the current injection the input receives a static signal 38 Rw_on Only combination with EDC-Sys and the ENEL feature Switch com- mand for resistor Rw 39 Rs2_on Only combination with EDC-Sys and the ENEL feature