100 mmSiphon
To internal drain
Extract AirFresh Air
Supply AirExhaust Air
Lack water siphon water damage
1%
.
This instruction must followed.
. IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT .
(Does not apply for GES)
2) Install airtight water trap non-freezing
location, compensate for fan pressure.
3) The water trap hight must least 100 mm.
It important have balance between supply
and exhaust air volumes
8) It recommended keep the ducts closed until
the unit adjusted and used.
5) Pour liter water into the driptray the unit verify
that drained properly. IMPORTANT IMPORTANT IMPORTANT IMPORTANT IMPORTANT .3Subject Technical Modifications Energy and 3/GES Energy 1
When installing the units follow these instructions:
1) Tilt the machine 10-15 towards the drainpipe
to allow condensing water run drain.
.
6) If freezing the water trap may occur, is
necessary install thermostat and electrical
heater prevent freezing, when the temperature
drops below +2C°.
4) Make sure that the drain flows downwards all the
way from the unit. the heating season
make sure that the drain properly filled with water. the drain not
made according this instruction, GENVEX A/S can
not made responsible for any additional damages,
which have nothing with the GENVEX unit.
7) Airflow adjustments must made both supply
and exhaust sides for normal use the machine