Passive Ventilation with Electric Diagram for Optima 100 and Optima 250

Autor: Genvex A/S

Strana 11 z 18

Jak získat tento dokument?






Poznámky redaktora
• The condensation outlet blocked ice. Change filter: - The filters must changed. • Blocked filter. 3) The device not running The device stops: No light the control panel, even when you press on the button. • The fuse the control system circuit board has blown. • Fresh air grill blocked with dirt and leaves the autumn snow and ice the winter. The heating coil can only reactivated with the reset button located on the terminal box when the temperature below 90°C. - Cable between display and circuit board long. The heat coil disconnects the configured value (90°C) exceeded. • The extraction fan defective. • water the water trap. • Discharge grill/roof cover blocked snow and ice in winter. The safety thermostat fitted the electric heatsurface’s terminal box. - The unit has stoppedthermostat/motor valve, incorrect setting control panel. Cold air supply: Error: • Counter current heat exchanger blocked snow and ice. (Only devices with water after-heat fitted). Error: • The fuse the terminal board has blown and there is power the device. • There wire loose between the device and the control panel. Stopped circulation pump, air heating pipe, defective thermostat/motor-operated valve, incorrect configuration control panel. Condensation water leaking from the device: Error: • Condensation outlet blocked dirt. • The outlet not adequately protected against ice. • The extraction filter blocked. 2) Safety thermostat electric heatsurface (auxiliary equipment): The safety thermostat protects the electric heat-surface against high temperatures during heat production. • One the fuses the circuit board has blown. No air extraction from wet rooms: Error: • Defective fan. Hold ON-OFF: - The filters have not been changed within the last days. 4) Error air side No air supply the rooms: Error: • Defective fan. Version error: - If the program the display section does not suit the controller.11Subject Technical Modifications Energy and 3/GES Energy 1 Fault finding 1) The display shows Optima 250 DESIGN: Data error: - No communication between the display and controller. • Blocked filter. If the error not one those listed above, please contact your installer the GENVEX customer centre. . • There loose wire and power the device. • Electric after-heat surface disconnected from safety thermostat (only device with electric heat-surface fitted) • circulation hot water the water after-heat surface. • The fuse the control system circuit board has blown