Frekvenční měniče Katalogy, manuály (EN+CZ)

| Kategorie: Katalog  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 639 z 825







Poznámky redaktora
M3 motors 500 600 Standard insulation system conjunction with du/dt filtering reinforced insulation. U Peak line line voltage motor terminals. Symbol Explanation Un Nominal mains voltage. the motor does not fulfil the following requirements, the lifetime the motor might shorten. 500 600 the insulation system withstands Ull=1800 du/dt filtering not required. Insulated N-end (non-driven end) bearings and or com ode filters are also required for motor bearing currents with motors bigger than 100 kW.2. Random-wound and Form-wound 420 500 the insulation system withstands Ull=1600 and At=0. HXR and motors ABB random-wound 380 690 Check motor insulation system with the motor manufacturer. The voltage can almost double the otor terminals, depending otor cable properties. 600 690 Reinforced insulation system conjunction with du/dt filtering. With du/dt filtering, the insulation system must withstand Ûll=1300 V.2009 Hardware options 29 . For information on the construction the motor insulation, consult the manufacturer. interval during which line line voltage motor terminals changes from 10% 90% full voltage range. Du/dt filtering suppresses inverter output voltage spikes and rapid voltage changes that stress otor insulation. Additionally, du/dt filtering reduces capacitive leakage currents and high frequency emission the otor cable well high frequency losses and bearing currents the motor. Non-ABB 420 Insulation system must withstand Ull=1300 V.Du/dt filters As with all frequency converters employing the most m odern inverter technology, the ACS800 output comprises regardless output frequency pulses of approximately 1. Filter selection table for ACS800 Motor type Nominal mains Motor insulation requirement vo|tage (UJ ABB and 500 Standard insulation system. With du/dt filtering, the insulation system must withstand Ûll=1800 V. 3AFE68248531 REV 20.3 ps, du/dt filtering not required.e. 600 690 the motor insulation system withstands Ull=2000 and At=0.35 times the mains network voltage with very short rise time. W hen needed? The need for du/dt filtering depends the motor insulation. With du/dt filtering, the insulation system must withstand Ull=1600 V. At Rise time, i.2 ps, du/dt filtering not required. For more information see the ACS800 hardware manuals. HXR and motors du/dt filtering with voltages over 500 V. ABB form-wound 380 690 Standard insulation system