Poznámky redaktora
2 3.3.2 4. The rated current the S800 must higher than equal the rated motor current achieve the rated motor power given the table. H eavy-duty use Ihd: continuous current allowing 150% Ihd for 1min/ min 40°C.2 4.2 0-1 04-0060-5 R5i 55 138 1.3 0-1 04-0016-5 R3i 15 0.3 0-1 04-0910-5 2xR8 i 900 1372 1991 900 1317 710 1026 14.0 0-1 04-0050-5 R5i 45 112 1.9 2.2 0.8 0-1 04-0040-5 R4i 37 1.2 4.2 0-1 04-0009-5 R2i 7.5 0.9 0-1 04-1210-5 8 R X 2 i 1400 2037 2956 1400 1956 1120 1524 22.7 0-1 04-0460-5 R8i 500 700 1016 450 672 355 524 7.0 7. 20 3AFE 68248531 REV 31.5 4.0 5.8 0-1 04-0120-5 R7i 110 164 270 110 157 135 2. Phd: typical motor power heavy-duty use.6 0-1 04-0030-5 R4i 30 0.7 0-1 04-0400-5 R8i 355 525 762 355 504 250 393 5.3 0-1 04-0260-5 R8i 250 365 530 250 350 160 273 3.Multidrive modules ratings, types and voltages Drive module, UN= 500 . Typical Ratings: No-overload use Pcont. Type Height Width Depth mm mm RDCU control unit 282 126 41 *) Delivered with every unit.5 5. Nominal Ratings: Icont. In lower temperatures the ratings are higher (except Imax).5 0-1 04-0100-5 R6i 90 135 224 130 112 1.5 0-1 04-0210-5 R8i 200 315 457 200 302 132 236 3.5 0-1 04-0025-5 R3i 22 18. Available for start, otherwise long as allowed drive temperature.5 7. Light-overload use In: continuous current allowing 110% for 1min/ min 40°C.1 0-1 04-0005-5 R2i 4 8. 3) The depth without without control panels and options.7 3.5 0.1 0-1 04-0140-5 R7i 160 250 363 160 240 110 187 2.5 3. ACS800 X04 0003 XXXX No-overload use Nominal ratings Light-overload use Heavy-duty use Heat dissipation kW M odule type Frame size Pcont.2004 .max kW Icontmax A A Pn kW In A Phd kW Ihd A UN 500 (Range V) 2.max: rated current available continuously without overloadability 40°C.5 9. Imax: maximum output current.2 0-1 04-0006-5 R2i 5.0 5.4 0-1 04-0070-5 R5i 75 112 168 108 1.2 0.4 0-1 04-0020-5 R3i 19 18.9 0-1 04-2430-5 4xR8 i Dimensions: Frame size Height Width Depth Weight Noise level Air flow mm dB(A) m3/h R2i 401 165 1933) 35 R3i 466 173 2323) 69 R4i 525 240 2523) 103 R5i 673 265 2763) 168 R6i1) 744 228 367 480 R7i1) 744 228 367 480 R8i 1397 235 596 150 1280 2xR8i 1397 2452) 596 300 2560 3xR8i 1397 2452) 596 450 3840 4xR8i 1397 2452) 596 600 5120 1) Dimensions not include cooling fan.3 0-1 04-0011-5 R2i 11 7.6 2.5 5.max: typical motor power no-overload use.6 0.5 0.4 0.5 1.9 0-1 04-0320-5 R8i 315 455 660 315 437 200 340 4. The ratings apply 40°C ambient temperature. PN: typical motor power light-overload use.1 0-1 04-0004-5 R2i 3 6. The current ratings are the same regardless the supply voltage within one voltage range.7 0-1 04-0610-5 R8i 710 1050 1524 710 1008 500 785 11.5 0.1 4. 2) Single module only.0 7.0 0-1 04-1820-5 8 R X 3 i 2000 2688 3901 1800 2580 1400 2011 28