Frekvenční měniče Katalogy, manuály (EN+CZ)

| Kategorie: Katalog  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 52 z 825







Poznámky redaktora
3 800-107-0210-7 R8i 200 215 322 200 206 160 161 800-107-0260-7 R8i 250 289 432 250 277 200 216 4.8 800-107-0120-7 R7i 160 170 254 160 163 110 127 3. One DCUcan used for two drive units.5 5.8 800-107-0050-7 R5i 45 800-107-0060-7 R5i 55 104 1.1 800-107-0070-7 R6i 75 130 1.4 800-107-0020-7 R4i 19 18.Multidrive ratings, types and voltages Drive unit, UN= 690 V ACS800 X07 0003 XXXX No-overload use Nominal ratings Light-overload use Heavy-duty use Heat dissipation kW Typ ecode Frame size Pcont. 3) 300 required for Drive Control Unit (DCU). 14 3AFE 68248531 REV 31. The rated current the S800 must higher than equal the rated motor current achieve the rated motor power given the table.max: typical motor power no-overload use.6 800-107-0320-7 R8i 315 336 503 315 323 240 251 5.max: rated current available continuously without overloadability 40°C .5 0. P typical motor power light-overload use.2004 .5 0. 5) Delivered with the back pack, the depth additional120mm.5 0. The current ratings are the same regardless the supply voltage within one voltage range. Phd: typical motor power heavy-duty use.5 0.5 8. An additional required for marine supports. 4) Delivered with additional cabinet(s), when top exit common motor output connection required.3.8 800-107-0440-7 R8i 450 486 727 450 467 355 364 7. In lower temperatures the ratings are higher (except Imax).5 800-107-0025-7 R4i 22 18. Nominal Ratings: Icont.4 800-107-0580-7 R8i 710 729 1091 710 700 500 545 800-107-0870-7 2xR8i 900 953 1425 900 914 710 713 800-107-1160-7 2xR8i 1400 1414 2116 1400 1358 1000 1058 800-107-1740-7 3xR8i 1900 1866 2792 1800 1792 1400 1396 800-107-2320-7 4xR8i 2300 2321 3472 2200 2228 1600 1736 800-107-2900-7 5xR8i 2800 2770 4144 2700 2659 2000 2072 800-107-3490-7 6xR8i 3200 3232 4835 3100 3103 2400 2417 800-107-4070-7 7xR8i 3700 3694 5526 3600 3546 2800 2763 800-107-4650-7 8xR8i 4200 4155 6216 4000 3989 3100 3108 800-107-5230-7 9xR8i 4600 4617 6907 5000 4432 3500 3454 800-107-5810-7 10xR8i 5100 5079 7598 5500 4876 3800 3799 800-107-6390-7 11xR8i 5600 5540 8288 6000 5319 4200 4144 800-107-6970-7 12xR8i Standard options: • Cable top exit • switch with capacitor charging circuits • Ground fault protection with current transformers) • Output du/dt filter, standard for parallel connected inverters • Common otor connection terminals with parallel connected inverters Dimensions Fram e size Height Width Width Depth Weight kg Noise level dB(A) Noise level dB(A)6) Air flow R4i 21301) 4002) 6005) 180 103 R5i 21301) 4002) 6005) 180 168 R6i 21301) 400 6004) 6005) 200 480 R7i 21301) 400 6004) 6005) 200 480 R8i 21301) 4003) 7003)4) 6005) 320 1280 2xR8i 21301) 6003) 9003)4) 6005) 510 2560 3xR8i 21301) 8003) 12003)4) 6005) 660 3840 4xR8i 21301) 12003) 16003)4) 6005) 1020 5120 5xR8i 21301) 14003) 18003)4) 6005) 1170 6400 6xR8i 21301) 16003) 22004) 6005) 1320 7680 7xR8i 21301) 20003) 26004) 6005) 1680 8960 8xR8i 21301) 22003)) 30004) 6005) 1830 10240 9x8Ri 21301) 24003) 32004) 6005) 1980 11520 10xR8i 21301) 28003) 38004) 6005) 2340 12800 11xR8i 21301) 30003) 42004) 6005) 2490 14080 12xR8i 21301) 32003) 44004) 6005) 2640 15360 1) Cabinet height 231 for classification and for XXR 2051 mm. Available for start, otherwise long as allowed drive temperature.max A Pn kW IN A Phd kW Ihd A Un V) 8 7. 6 Average noise level with controlled cooling fan. 2) 1-3 R2i, 1-3 R3i, 1-2 R4i, 1-2 R5i.7 800-107-0040-7 R4i 37 0. The ratings apply 40°C ambient temperature.3 800-107-0011-7 R4i 11 7. Light-overload use IN: continuous current allowing 110% for 1min/ min 40°C. H eavy-duty use Ihd: continuous current allowing 150% Ihd for 1min/ min 40°C.3 800-107-0016-7 R4i 15 0.2 800-107-0400-7 R8i 355 382 571 355 367 270 286 6.6 800-107-0030-7 R4i 30 0.max kW Icont.5 800-107-0100-7 R7i 90 105 176 101 1. Typical Ratings: No-overload use P cont. Imax: maximum output current