Poznámky redaktora
98 (fundamental)
c 0.2 100 Hz: 0.95 (total)
Power factor 800-11/-31/-17/-37)
c (fundamental)
cosqi 0.2% sec.01% nominal speed
Dynamic accuracy:
0.14-95, C-Tick, GOST R
E iro lim its
Am bient tem perature
Transport
Storage
Operation
-40 +70 °C
-40 +70 °C
-15 +50c, frost allowed
Operation
(ACS800-07LC)
40 reduced output current
(1% °C)
0 +55 frost allowed
+45 reduced output current
(1% °C)
Cooling method: Dry clean air
Cooling method:
(ACS800-07LC)
Cooling liquid:
Direct liquid-cooling
+38 max custom circuit, fresh ater or
sea ater (optional liquid-cooling unit)
+38 +45 reduced output current
1% °C
+42 max converter circuit, fresh water
+42 +48 reduced output current
1% °C
Altitude
0 1000 m
1000 4000 m
without derating
with derating (1% 100 m)
(690 units 1000 2000 with derating)
Relative humidity 95%, condensation allowed
Degree protection
IP21
IP22
IP42
IP54
IP54R
IP55
standard for -01, -11, -31, -02, -07, -17, -37
option for -07, -17, -37
standard for -07LC, option for -07, -17, -37
option for -07, -07LC, -17, -37
option for -07, -17, -37
option for -01
R outlet air duct connection
Paint colour -07, -07LC, -17, -37: RAL 7035
-01, -11, -31, -02: NCS 1502-Y
(RAL 9002, PMS 420 C)
Contam ination levels conductive dust allowed
Storage IEC60721-3-1, Class 1C2 (chemical gases),
Class 1S2 (solid particles)
Transportation IEC60721-3-2, Class 2C2 (chemical gases),
Class 2S2 (solid particles)
Operation IEC60721-3-3, Class 1/3C (chemical
gases), Class 3S2 (solid particles)
Vibration marine
classification
3 13. with 100% torque step
0.1 0.2 Hz: plitude (peak)
13.4% sec. with 100% torque step
P lia e
CE
Low Voltage Directive 73/23/EEC ith endm ent 93/68/EEC
Machinery Directive 98/37/EC
EMC Directive 89/336/EEC ith endm ent 93/68/EEC
Quality assurance system ISO 9001 and
Environmental system ISO 14001
UL, 508A 508C and CSA C22.2 NO.99 (total)
Efficiency (at nominal power)
A S800-0x
A S800-1x/-3x
98%
97%
M tio n
Voltage
for 500 units
3 -Phase output vo|tage in^ in
please see Filter selection table for
AC S800” under the du/dt filters page 37
Frequency ±300 Hz
(0 +-120 with optional /dt filters)
Field eakening point 300 Hz
M otor control ABB's Direct Torque Control (DTC)
Torque control:
Open loop
Closed loop
Torque step rise time:
<5 with nominal torque
<5 with nominal torque
Open loop
Closed loop
Non-linearity:
±4% with nominal torque
±3% with nominal torque
Speed control:
Open loop
Closed loop
Open loop
Closed loop
Static accuracy:
10% otor slip
0. Please see pages 58-59.2.7 acceleration
C chem ically active substances
S echanically active substances
* coated circuit boards
E ),
EN )
2nd environment, unrestricted distribution, category standard in
-07 (frame size nxR8i), -07LC, -17 and -37 (frame sizes R7i-nxR8i),
option the others
1st environment, restricted distribution (category C2) options to
1000 input current
Available options are shown the Sum ary features and options
table.3 0.
12 Product series 68375126 REV 17.2009
.93 0.Technical specification
A 1
11
31
0 2
07
07LC
17
37
XXXX XXXX
M tio n
Voltage and
pow range
3-phase, U2|N 208 240 10%,
except -07, -07LC, -17, -37
3-phase, U3|N 380 415 10%
3-phase, U5|N 380 500 10%
3-phase, U?|N 525 690 10%
(600 UL, CSA)
Frequency Hz
Power factor 0