Poznámky redaktora
Perform blind control via different RCCB
To avoid unwanted activation the RCCB, the circuits must decou-
pled via blind cut-off relay. 0399 00
Technical data
Rated voltage:
(N conductor required)
AC 230V~, 50Hz
Switching capacity: max. 1000VA
Relay output: equipotential-bonding con-
tacts (interlocked)
Pulse duration: 2min
Changeover time
with extended run: least 1s
electronic lock via top unit)
Connection terminals: Screw terminals for
max. this not desired, use blind
switches with mechanical locks. The blind must moved the
desired position via manual actuation.5mm² 2×1.
1
2 N
L 1
2 N
L
L
AC 230 ~
0398 0398 00
N
M
RCD
RCD
1 2
Connection example two RCD circuits
1 RCCB, RCD
2 blind cut-off relay
Blind controller insert without
auxiliary input
Order No.5mm² 2×1. 16A
(A)
Connection blind controller insert with mechanical auxiliary unit (blind button
with mechanical lock)
Explanation (A)
0154 00, 0157 Blind button blind switch insert
0154 Water-protected surface-mounted blind button
or blind switch
0158 13, 0159 Surface-mounted blind rocker button blind
rocker switch
0144 00, 0163 Key switch inserts
0144 30, 0163 Water-protected surface-mounted key switches
Connection blind controller insert auxiliary unit
When using blind buttons, the blind controller insert does not switch to
self-locking mode (extended run). 1000VA
Relay output: equipotential-bonding NO
contacts (interlocked)
Pulse duration: 2min
Changeover time
with extended run: least 1s
(electronic ock via top unit)
Connection terminals: Screw terminals for
max. 2. 0398 00
Technical data
Rated voltage:
(N conductor required)
AC 230V~, 50Hz
Switching capacity: max. 2.5mm²
Circuit breaker: max.654 Gira electrical installation systems
Blind controller Inserts
I
Technical
information
Blind controller insert 230V~
with auxiliary input
Order No.
Note
As long raise command active auxiliary input “2”, the blind
cannot operated manually automatically the device itself.5mm²
Connection blind controller insert without auxiliary unit