Poznámky redaktora
5mm²
Circuit breaker: max.
Note
As long there command auxiliary unit input “2”, the
blinds can neither operated manually nor automatically.2 0.5mm²
Circuit breaker: max. 120 seconds
Connection terminals:
1-wire
Fine-wire with core jacket
0.
L
AC 230 ~
5414 5414 00
N
M
RCD
RCD
1 2
N
L
2
1 N
L
2
1
Connection example two RCD circuits
1 RCCB, RCD
2 Blind cut-off relay page 656
N
L
2
1
L N
5414 00
System 3000 blind control insert with wind sensor auxiliary connection
System 3000
Blind control insert
without auxiliary input
Order No. 700W
Standby power: 0.5W
Contact type: contact
Runtime: approx.
N
L
2
1
(A)
5414 00
System 3000 blind control insert with auxiliary connection
Explanation (A)
0154 00, 0157 Blind button blind switch insert
0154 Water-protected surface-mounted blind button
or blind switch
0158 13, 0159 Surface-mounted blind rocker button blind
rocker switch
0144 00, 0144 Key switch inserts, SM
0163 00, 0163 Key button inserts, SM
0913 Wind sensor auxiliary unit
5415 System 3000 blind control insert
L1
N
N
L
(A)
N
L
2
1
5414 00
N
L
2
1
5414 00
L2
N
M
M
Connection example: Group control, System 3000 blind control insert
The “TEST” button allows you control the connected motor without a
top unit, order set the motor’s end positions. 5415 00
Technical data
Rated voltage: 230V~, 50/60Hz
Connected load the motor: max.653
Gira electrical installation systems
System 3000 inserts Blind controller
I
Technical
information
System 3000
Blind controller insert with
auxiliary input
Order No.5 2. 120 seconds
Connection terminals:
1-wire
Fine-wire with core jacket
from 0. 5414 00
Technical data
Rated voltage: 230V~, 50/60Hz
Connected load the motor: max.5W
Contact type: contact
Runtime: approx.5 2.2 0. 16A
Information accordance with
DIN 60730-1
Method: 1.
Perform blind control via different RCCB
To avoid unwanted activation the RCCB, the circuits must decou-
pled via blind cut-off relay. 16A
Information accordance with
DIN 60730-1
Method: 1.B
Pollution level: 2
Rated surge voltage: 4,000V
N
L
5415 00
System 3000 blind control insert without auxiliary connection
.5 4mm²
from 0. 700W
Standby power: 0.B
Pollution level: 2
Rated surge voltage: 4,000V
Note
System 3000 control inserts can only operated with System 3000 top
units.5 4mm²
0