Poznámky redaktora
mm² Dimensions - - Modular widths (MW): 8 Scope supply - - KNX connection and junction terminal included the scope of supply. KNX switching actuator, 8-gang with manual actuation KNX switching actuator, 8-gang with manual actuation and current measurement for C-loads . - - Independent switching the eight outputs. mm² Current detection: 0. - - Threshold values for load monitoring (e. signalling load failure). - - The switching actuator has integrated current detection. Technical data Relay - - Number: 8 - - Contact: zero-voltage contact each, flip-flop Switching capacity 230 AC1 AC3 Switching capacity 400 AC1 AC3 Maximum switch-on current: 600 150 µs, 300 600 µs Connected load - - Ohmic load: 3680 W - - Capacitive load 230 max. 200 µF - - Light bulbs: 3680 W - - halogen lamps: 3680 W - - Wound transformer: 2000 VA - - Gira Tronic transformer: 2500 W - - Fluorescent lamps, uncompensated: 3680 VA - - Fluorescent lamps, duo- circuit: 3680 VA - - Fluorescent lamps, parallel- compensated: 2500 VA - - Mercury-vapour lamps, uncompensated: 3680 W - - Mercury-vapour lamps, parallel-compensated: 3680 W Connections: max. unit PS Gira electrical installation systems Price system (PS) 14: reduced discount KNX system devices, actuators, sensors DRA plus 100600 1006 1/100 26 Features - - Independent switching the eight outputs.518 KNX Switching Specifications Order No. unit Specifications Order No. DRA plus 104600 1046 1/100 66 Features - - The switching contacts the switching actuator, 8-gang, C-load are especially designed for loads with capacitive character, and therefore conditional, brief, high switch-on currents (see Technical Data). Technical data Relay - - Number: 8 - - Contact: zero-voltage contact each, flip-flop Switching capacity 230 AC1 AC3 Switching capacity 400 AC1 AC3 Switching capacity - - DC: A/24 V - - DC: A/24 V Maximum switch-on current: 400 150 µs, 200 600 µs Connected load - - Ohmic load: 3600 W - - Capacitive load 230 max.g. 140 µF - - Light bulbs: 2500 W - - halogen lamps: 2500 W - - Wound transformer: 1200 VA - - Gira Tronic transformer: 1500 W - - Fluorescent lamps, uncompensated: 2500 VA - - Fluorescent lamps, duo- circuit: 2300 VA - - Fluorescent lamps, parallel- compensated: 1300 VA - - Mercury-vapour lamps, uncompensated: 2000 W - - Mercury-vapour lamps, parallel-compensated: 2000 W Connections: max. - - current measurement can carried out for each channel. - - Current detection: Measurement load current for each channel.25 sine Dimensions - - Modular widths (MW): 8 Scope supply - - KNX connection and junction terminal included the scope of supply