This Notification of Test Results is the result of testing a sample of the product subrrft ed, in acc rdancewith the provisions of the relevant specific standard.
...................103 mm2 P
force (N) (table 104) ......... 0,54 0,54 0,55 P
- voltage drop measured (mV) (5*11deflection)......................................... 0,61 0,60 0,59 P
- voltage drop measured (mV) (9111deflection)..... 0,61 0,60 0,60 P
- voltage drop measured (mV) (10thdeflection). 0,61 0,58 0,56 P
- voltage drop measured (mV) (6thdeflection)........ P
Distance (mm) (table 104)......................... 0,60 0,57 0,55 P
- voltage drop measured (mV) (7thdeflection).... 0,60 0,58 0,59 P
- voltage drop measured (mV) (8thdeflection)...IEC 60998-2-2
Clause Requirement Test Result Remark Verdict
14. 0,58 0,58 0,58 P
- requirement: 2,5........... 0,61 0,60 0,60 P
- voltage drop measured (mV) (3rt deflection)........... 0,57 0,54 0,54 P
- voltage drop measured (mV) (4thdeflection)... 0,59 0,58 0,58 P
- voltage drop measured (mV) (11thdeflection)... 0,59 0,58 0,59 P
- voltage drop measured (mV) (12* deflection)... 100 P
-screwless terminál number -
- voltage drop measured (mV) (1st deflection)........ 3,2 P
smallest cross-sectional area (mm2) 10..........101 TABLE: Mechanical strength
0,1 times the test current (A)................ 0,62 0,57 0,60 P
- voltage drop measured (mV) (2nddeflection)