This Notification of Test Results is the result of testing a sample of the product subrrft ed, in acc rdancewith the provisions of the relevant specific standard.
..101 the test conductor, properly inserted into clamping unit the connection devices
shall allowed bent (deflected) all directions each them differing from
the adjacent directions 30° 5°
Deflection test (principle test apparatus shown figuře 103a):
- requirement: 2,5 See appended table 14.101 P
max measured voltage drop (mV) 0,62 P
14..DEKRA
IEC 60998-2-2
Clause Requirement Test Result Remark Verdict
14 MECHANICAL STRENGTH
14.: T-marking: P
Maximum voltage drop did not exceed 22,5 or
1,5 times 24thcycle value
See appended table 15.3 Impact test (for g): blows:
- height fail: 7,5 N
- height fall: N
- height fall: N
- height fall: N
After the test, damage and live parts shall not
become accessible
N
15 TEMPERATURE RISE
requirement: 45K P
max measured temperature rise (K) See appended table P
15......2 Tumbling barrel (for g): falls; after the test
no damage
4,15 g
P
14...101 192 temperature cycles test, each cycle with a
duration with the test current defined in
Table Part I
P
Cabinet temperature (°C).........................101
P
...