g. unit PS
Gira electrical installation systems Price system (PS) 14: reduced discount
KNX
system
devices,
actuators,
sensors
DRA plus 222400 2224 26
Features
-
- The controller unit switches and dims electrical devices that have
a 1-10 interface. 500 0.
-
- Energy-saving function: Switch-off the power supply the
DALI operating devices possible switched-off state (via
additional KNX switching actuator).
Switching actuator operation (optional)
-
- Independent switching switch outputs A4.
-
- Feedback switching condition and brightness value.
-
- Feedback from the switching condition.
-
- Time functions (switch-on, switch-off delay, staircase light
function also with advance warning function). operating
devices).
-
- Dimming behaviour and dimming characteristics can be
parameterised.
-
- Five device configurations can selected.
KNX control unit 4-gang with manual
actuation
KNX DALI gateway Plus
.
-
- Group feedback all switching conditions possible.
-
- Control max.
-
- Effect control can configured for max.
-
- three central switching functions for the joint control all
dimming and switching channels.
-
- Manual actution outputs independent the bus with
mechanical switching position indication. unit Specifications Order No. DALI operating devices individual control,
group control max. four dimming channels are assigned
to one switching relay control RGBW light).
Technical data
KNX medium: TP1-256
Relay
-
- Number: 4
-
- Contact: zero-voltage contact
each, flip-flop
Control outputs
-
- Control voltage: V
-
- Control current per output: max.
-
- Switch-on times the relay outputs can recorded and
evaluated the elapsedoperating time meter.
-
- Active passive (object can read out) cyclical feedback
function.
-
- The groups can integrated the light scenes. For this
reason, use switch-on current limiter separate load contact
for with greater loads. sequences to
500 run-throughs (or infinite).
-
- Cyclical monitoring incoming switching telegram is
configurable.
-
- Dimmable brightness range can set.
-
- The burning-in function allows for the start-up new fluorescent
lamps prescribed lighting manufacturers.
-
- Time functions (switch-on delay, switch-off delay, staircase light
function).5 mm²
Switching outputs
-
- Switching voltage: 250/400 V
-
- Switching current 230 AC1: A
-
- Switching current 230 AC3: A
-
- Switching current 400 AC1: A
-
- Switching current 400 AC3: A
-
- Fluorescent lamps: AX
Lamp loads
-
- Light bulbs: 3680 W
-
- halogen lamps: 3680 W
-
- Wound transformer: 2000 VA
-
- Gira Tronic transformer: 2500 W
Fluorescent lamps T5/T8
-
- Uncompensated: 3680 W
-
- Parallel-compensated: 2500 W/200 µF
-
- Duo-circuit: 3680 W/200 µF
Compact fluorescent lamps
-
- Uncompensated: 3680 W
-
- Parallel-compensated: 2500 W/200 µF
Mercury-vapour lamps
-
- Uncompensated: 3680 W
-
- Parallel-compensated: 3680 W/200 µF
Ambient temperature: +45 °C
Connections
-
- KNX: Connection and junction terminal
-
- Screw terminals
-
- Load: Screw terminals
-
- max.
Scope supply
-
- KNX connection and junction terminal included the scope of
supply. mm²
Dimensions
-
- Modular widths (MW): 4
Notes
-
- Electronic ballasts generate very high current spikes.
-
- contact contact operation.526
KNX Dimming
Specifications Order No.
-
- Logical linking function configurable per channel.
-
- Delay for actively transmitted feedback messages following bus
voltage recovery. groups, central control via a
broadcast telegram (group each with max.
-
- Block function forced setting function can parameterised.
-
- light scenes. ten internal scenes
per switching output are programmable.
Dimming channels
-
- Four individually-controllable dimming channels.
-
- Feedback DALI error status short circuit and signalling of
power supply failure.
-
- Can integrated the light scenes.
-
- Relay outputs that are not associated with dimming channel
can used freely-acting switching actuator channel.
-
- Soft switch-on and soft switch-off function
-
- Block function forced setting function can parameterised.
-
- Reactions case bus voltage failure and restoration can be
set following ETS programming process. This leads the
assignment four individually-controllable dimming channels to
the switching outputs (e. With the staircase light function, the reaction the
end the switch-on time can configured.
-
- Inclusion dimming channel ten scenes possible.
-
- Manual actuation the devices also independent the bus (also
building site operation with broadcast control).
DRA plus 218000 2180 66
Features
-
- The DALI gateway Plus forms the interface between KNX
installation and digital DALI lighting system. 100 mA
-
- Cable length: max