Catalogue 2019 Intelligent building technology by Gira

| Kategorie: Katalog  | Tento dokument chci!

Vydal: SBS ELEKTRO s.r.o.

Strana 528 z 696







Poznámky redaktora
g. unit PS Gira electrical installation systems Price system (PS) 14: reduced discount KNX system devices, actuators, sensors DRA plus 222400 2224 26 Features - - The controller unit switches and dims electrical devices that have a 1-10 interface. 500 0. - - Energy-saving function: Switch-off the power supply the DALI operating devices possible switched-off state (via additional KNX switching actuator). Switching actuator operation (optional) - - Independent switching switch outputs A4. - - Feedback switching condition and brightness value. - - Feedback from the switching condition. - - Time functions (switch-on, switch-off delay, staircase light function also with advance warning function). operating devices). - - Dimming behaviour and dimming characteristics can be parameterised. - - Five device configurations can selected. KNX control unit 4-gang with manual actuation KNX DALI gateway Plus . - - Group feedback all switching conditions possible. - - Control max. - - Effect control can configured for max. - - three central switching functions for the joint control all dimming and switching channels. - - Manual actution outputs independent the bus with mechanical switching position indication. unit Specifications Order No. DALI operating devices individual control, group control max. four dimming channels are assigned to one switching relay control RGBW light). Technical data KNX medium: TP1-256 Relay - - Number: 4 - - Contact: zero-voltage contact each, flip-flop Control outputs - - Control voltage: V - - Control current per output: max. - - Switch-on times the relay outputs can recorded and evaluated the elapsedoperating time meter. - - Active passive (object can read out) cyclical feedback function. - - The groups can integrated the light scenes. For this reason, use switch-on current limiter separate load contact for with greater loads. sequences to 500 run-throughs (or infinite). - - Cyclical monitoring incoming switching telegram is configurable. - - Dimmable brightness range can set. - - The burning-in function allows for the start-up new fluorescent lamps prescribed lighting manufacturers. - - Time functions (switch-on delay, switch-off delay, staircase light function).5 mm² Switching outputs - - Switching voltage: 250/400 V - - Switching current 230 AC1: A - - Switching current 230 AC3: A - - Switching current 400 AC1: A - - Switching current 400 AC3: A - - Fluorescent lamps: AX Lamp loads - - Light bulbs: 3680 W - - halogen lamps: 3680 W - - Wound transformer: 2000 VA - - Gira Tronic transformer: 2500 W Fluorescent lamps T5/T8 - - Uncompensated: 3680 W - - Parallel-compensated: 2500 W/200 µF - - Duo-circuit: 3680 W/200 µF Compact fluorescent lamps - - Uncompensated: 3680 W - - Parallel-compensated: 2500 W/200 µF Mercury-vapour lamps - - Uncompensated: 3680 W - - Parallel-compensated: 3680 W/200 µF Ambient temperature: +45 °C Connections - - KNX: Connection and junction terminal - - Screw terminals - - Load: Screw terminals - - max. Scope supply - - KNX connection and junction terminal included the scope of supply. mm² Dimensions - - Modular widths (MW): 4 Notes - - Electronic ballasts generate very high current spikes. - - contact contact operation.526 KNX Dimming Specifications Order No. - - Logical linking function configurable per channel. - - Delay for actively transmitted feedback messages following bus voltage recovery. groups, central control via a broadcast telegram (group each with max. - - Block function forced setting function can parameterised. - - light scenes. ten internal scenes per switching output are programmable. Dimming channels - - Four individually-controllable dimming channels. - - Feedback DALI error status short circuit and signalling of power supply failure. - - Can integrated the light scenes. - - Relay outputs that are not associated with dimming channel can used freely-acting switching actuator channel. - - Soft switch-on and soft switch-off function - - Block function forced setting function can parameterised. - - Reactions case bus voltage failure and restoration can be set following ETS programming process. This leads the assignment four individually-controllable dimming channels to the switching outputs (e. With the staircase light function, the reaction the end the switch-on time can configured. - - Inclusion dimming channel ten scenes possible. - - Manual actuation the devices also independent the bus (also building site operation with broadcast control). DRA plus 218000 2180 66 Features - - The DALI gateway Plus forms the interface between KNX installation and digital DALI lighting system. 100 mA - - Cable length: max