Catalogue 2019 Intelligent building technology by Gira

| Kategorie: Katalog  | Tento dokument chci!

Vydal: SBS ELEKTRO s.r.o.

Strana 653 z 696







Poznámky redaktora
5mm² 110W 105W 2. 0. Can dimmed with Gira Tronic dimmer and Gira universal dimmer (trailing edge dimmer).651 Gira electrical installation systems Tronic transformers I Technical information Tronic transformers Dimensions Transformer Dimensions (mm) (A) (B) (C) (D) (E) 0367 40W 3. Control occurs via 1–10V control unit such the built-in control unit for 1–10V, electronic potentiometer for 1–10V con- trol input System 2000 1–10V control unit insert. Overload and excess-temperature protection via auto- matic power reduction (40/70/105/150W transformers) switch-off until cool-down (200W transformer).7 Veff, ~ 40kHz Primary current: 0.5mm² VV-F 2×1. Short-circuit protection (200W transformer): Switch-off with automatic restart after elimination short circuit within five seconds. Tronic transformer with integrated 1–10V control device Order No. Any other switch-off remains until manual switch-on. 200W transformer also suitable for 230V. Bulb-saving switch-on due soft-start. Underload could lead flickering.4 3. AC 230 ~ Control unit for 1–10V with Tronic transformer with integrated 1–10V control unit . +100°C Potentiometer for 1–10V interface with Tronic transformer with integrated 1–10V control unit The 1–10V top unit allows control the Tronic transformer via the 1–10V interface.8mA Electrical isolation 1–10V: 2kV basic insulation Ambient temperature (Ta ): max.5 55 0365 105W 4. Install isolated load circuit protect against overloads (caused by switching fluorescent lamps, discharge lamps, motors and other induc- tive loads) for Gira Tronic dimmers, Gira universal dimmers and Gira Tronic transformers. Short-circuit protection (40/70/105/150W transformers) Switch-off with automatic restart after elimination short circuit.5 181 63 (A) (B) (C) (D) (E) Minimum ceiling opening (E) with standard intermediate ceiling height 78mm.5mm² 155W 200W Power divided over least cables.75mm² 40W 105W 1. length the secondary line: 2m Min.5 148 60 0375 200W 4.75mm² VV-F 0. 0359 00 Technical data Rated voltage UN : 230V~, 50Hz Rated output: 105W Output voltage: 11. distance to earthed surface: 40cm Permissible number of secondary lines: 1 Technical data 1–10V interface Control voltage: 10V Control current: approx. +50°C Housing temperature (Tc ): max. Installation instructions Tronic transformers are spike-resistant accordance with 61047. (at least 2×1.5mm² VV-F 2×2.5mm²) Function Insert for 12V halogen lamps.5 3. this not heeded, defects may arise the Gira Tronic transformer due voltage spikes when switching the circuit. Note output range the transformer.4 40 0366 70W 3.5 148 54 0373 150W 4.45A (105W) Max. Power per cable Cable cross section Secondary line recommendation ≤ 35W 0.5 53 0371 105W 3