Catalogue 2019 Intelligent building technology by Gira

| Kategorie: Katalog  | Tento dokument chci!

Vydal: SBS ELEKTRO s.r.o.

Strana 628 z 696







Poznámky redaktora
- In multiple combinations, other standard socket outlets used the combination are also protected (when installed the same phase) when socket outlet with overvoltage protection used. - We recommend using additional medium and coarse protection with high-power overload pulses. - Electrical installations upstream the RCD-protected socket outlet or RCCB are not protected. Information operation - Keep cables between consumers and overvoltage protection socket outlets short possible, max. 16A (gG/C) Ambient temperature: -5°C 25°C Relative humidity: 95% (without condensation) Connection sensor head 1. Technical data Overvoltage protection: Arrester type (one port) Rated voltage: 230V 10%) Mains frequency: 60Hz Maximum continuous voltage: 255V (UC) No-load voltage: 4kV (UOC Rated load current: 16A (IL ) Short-circuit protection: 1. - This device works like residual current circuit breaker. Technical data Rated voltage: 230V~ Rated current: 16A Rated fault current: 30mA Connection cross sections: 1. There a risk surge voltage coupling. The socket outlet must replaced professional electrician.5 2. 2664. 0451. The socket outlet separates the protective branch from the mains network via thermal release during thermal overload (due to overloads which occur too frequently and strong overloads).. varistor reduces excess voltages.5kV (UP ) TOV characteristics: 442V/5s/120min (UT ) Circuit breaker: max. VDE 0664.. 2677.5 mm2 max. RCCB 30mA Order No. - Residual current protection applies all devices cables connected to the RCD-protected socket outlet the RCCB. T RCD-protected socket outlet 30mA with integrated increased contact protection (shutter) and symbol Order No. Connection SCHUKO socket outlet with overvoltage protection Functional description Socket outlet for the protection sensitive electrical and electronic devices from voltage spikes (transient overloads). . Features - The socket outlet used device protection (fine protection) - Disconnection the signal tone unplugging the power plug. L‘ N‘ L N L PEN TN-C AC 230 V~ L‘ N‘ L N L N PE TN-S AC 230 V~ Connection diagram TN-C mains Connection diagram TN-S mains L‘ N‘ L N L N TT main PE AC 230 V~ Connection diagram mains Functional description Socket outlet for use areas which residual current devices pursuant to VDE 0664 are indicated, for example in - rooms with bathtub shower (DIN VDE 0100, Part 701) - indoor swimming pools (DIN VDE 0100, Part 702) - agriculture (DIN VDE 0100, Part 705) - classrooms (DIN VDE 0100, Part 723). - Other socket outlets can connected the RCD-protected output terminals (L’ and N’).5mm² Ambient temperature: -25°C +40°C Function - The devices RCD-protected socket outlet and RCCB are permanently installed protective devices with voltage-dependent residual current tripping acc. audible signal emitted.25kV (UP ) Protection level (L/PE; N/PE): 1.5 2.5kA (ISCCR) Protection level (L/N): 1. The socket outlet supplies connected devices with mains voltage, but does not protect them. m AC 230 V~ 0451 0188 .626 Gira electrical installation systems RCD-protected socket outlet and RCCB socket outlet with overvoltage protection I Technical information SCHUKO socket outlet 16A 250V~ with overvoltage protection Order No... 4m. - Do not lay protected cables parallel unprotected cables