Poznámky redaktora
ms
Number inputs: 8
Output
-
- Voltage: SELV
-
- Electricity: max.536
KNX Anologue Sensor Interface Universal button interfaces
Specifications Order No. mm²
Dimensions
-
- Modular widths (MW): 4
Scope supply
-
- KNX connection and junction terminal included the scope of
supply. Hz
Rated frequency AC-signal: Hz
Signal duration: min.
-
- Two independent switching objects are available for each input
and can released individually, command for leading and
trailing edge can set independently (ON, OFF, CHANGE, no
reaction), cyclical transmission the switching object depending
on the edge depending the object value can selected. The switching operations of
zero-voltage contacts are converted into KNX telegrams.
-
- Telegram rate limit. unit PS
Gira electrical installation systems Price system (PS) 14: reduced discount
KNX
system
devices,
actuators,
sensors
DRA plus 212800 2128 66
Features
-
- The binary input has eight independent inputs the voltage
range that are connected the electrical signals.
Technical data
KNX medium: TP1-256
Ambient temperature: +45 °C
Dimensions mm
W 15
KNX binary input 8-gang AC/DC/
zero-voltage
Universal button interfaces
.
-
- The binary input has separate auxiliary voltage (SELV)
available for connecting zero-voltage contacts.
Function switching counter:
-
- edge for counting the signals the input and maximum meter
reading selectable, increment for the counter reading output and
telegram when the maximum meter reading reached can be
parameterised.
Technical data
Rated voltage: AC/DC V
Signal voltage
-
- for "0" signal: -48 V
-
- for "1" signal: V
Input current rated voltage: mA
Rated voltage S0: max.
-
- Possibility connect meters with interface (e.g. V
Pulse frequency S0: max.
Function switching output:
-
- Behaviour case bus failure and return, switch-on/off delay or
time switch function, output clocking (flashing LED).
Temperature value transmitter and brightness value
transmitter function:
-
- edge and value configurable, value adjustment with push button
is possible pressing and holding button. mA).
Pulse counter function:
-
- edge for pulse counting and interval time for meter reading
transfer can configured, edge the synchronisation signal for
resetting the meter reading and switching telegram when
synchronisation signal arrives can set. The inputs can parameterised as
outputs (max.
Features
-
- Blocker for blocking individual inputs. energy, gas,
water meter).
-
- Status message case error with the auxiliary voltage the
bus can removed.
-
- Behaviour upon bus voltage recovery can configured
separately for each input. unit Specifications Order No.
Flush-mounted binary inputs, can used deep device box
(60 deep) behind conventional switch/push button, for
connection zero-voltage contacts.
-
- Evaluation direct current voltage signals (DC) alternating
current voltage signals (AC).
-
- Single-surface and double-surface operation, time between
dimming and switching, and dim-step size can set, telegram
repetition, and stop telegram transmission possible.
Value transmitter and light scene auxiliary unit function:
-
- edge (button contact, button contact, switch) and
value with edge can configured, value adjustment with button
by pressing and holding button for value transmitters possible,
light scene auxiliary unit with memory function and saving the
scene without previously calling possible.
-
- Command can set with rising edge (no function, UP, DOWN,
CHANGE), operating concept can configured (Step Move -
Step Move Step), time between short and long-term
operation can set, slat adjustment time can set. mA
Connections
-
- KNX: Connection and junction terminal
-
- Inputs: Screw terminals
-
- max. The
inputs can assigned various functions blocked independently
of each other the process