Poznámky redaktora
For controlling electrically operated
blinds, shutters, awnings, ventilation flaps, similar hangings.
-
- Assignments five different safety functions (three wind
alarms, one rain alarm, one frost alarm) optionally with cyclical
monitoring. unit Specifications Order No.
DRA plus 215400 2154 1/100 26
Features
-
- For low voltage V.
Scope supply
-
- KNX connection and junction terminal included the scope of
supply.
-
- Extended sun protection with extensive control functions.
-
- Sun protection function with fixed and variable curtain slat
positions can activated.
-
- Central control all blind outputs possible.
Technical data
Rated voltage: V
Switching voltage DC: V
Switching capacity
-
- 12/24 A
-
- A
Connections: max.
Technical data
KNX medium: TP1-256
Connections
-
- KNX: Connection and junction terminal
-
- Load: Screw terminals
Notes
-
- Installation DIN top-hat rail.
-
- Integration scenes possible, internal scenes the most
can parameterised per channel.
KNX switching actuator, 16-gang blind
actuator, 8-gang with manual actuation
Blinds
KNX blind actuator, 4-gang with manual
actuation
.
-
- Behaviour after bus voltage failure and recovery can set. mm²
Dimensions
-
- Modular widths (MW): 8
Notes
-
- VDE approval accordance with 60669-1, 60669-2-1.
-
- Building site operation: Outputs can operated manually
without bus voltage with operating voltage only. mm²
Dimensions
-
- Modular widths (MW): 4
Scope supply
-
- KNX connection and junction terminal included the scope of
supply.
-
- Forced setting function can realised for each blind output.
-
- Separately parameterisable movement times with movement time
extension for moving into the upper end position.520
KNX Switching blinds Blinds
Specifications Order No.
-
- Blocking individual outputs manually with bus.
-
- Integration temperature management building possible.
-
- Independent control the four blind outputs.
-
- Memory function for light scenes.
-
- Feedback can delayed until after the recovery bus voltage.
Blind actuators with integrated bus coupler, manual activation, and
status display for each output.
Technical data
Relay
-
- Number:
-
- Contact: zero-voltage contact each
Current capacity
-
- neighbouring outputs: Total A
-
- Device: Total 160 A
Connections: max.
-
- Active passive (object can read out) cyclical feedback
functions.
-
- Independent switching switching outputs.
-
- Slat position can directly controlled.
Features
-
- Curtain position can directly controlled. unit PS
Gira electrical installation systems Price system (PS) 14: reduced discount
KNX
system
devices,
actuators,
sensors
DRA plus 103800
1038 1/100 66
Features
-
- Independent control eight blind outputs.
-
- Feedback the curtain position slat position