Catalogue 2019 Intelligent building technology by Gira

| Kategorie: Katalog  | Tento dokument chci!

Vydal: SBS ELEKTRO s.r.o.

Strana 476 z 696







Poznámky redaktora
- - Operating modes can adapted individually. The respective range functions depends the firmware used. cm - - Detection range: 30° horizontal, 30° vertical KNX medium: KNXnet/IP KNX standards - - DPTs value transmitter: 5. Integration Internet services - - Gira weather service: display the weather forecast for to five cities (internet connection required). Features - - Operation via gesture-capable multi-touch display.010, 5.474 Gira HomeServer, Gira FacilityServer Specifications Order No.xxx Protection type: IP21 Ambient temperature: +45 °C Dimensions mm - - Gira (incl.001, 14.001, 9. - - Room temperature controller combination with the temperature sensor module (available optional extra), or KNX devices for room temperature measurement, e. - - Switching and dimming (relative and absolute), dimming (incl. black glass 206905 2069 36 white glass 206912 2069 36 Functional description D463 Gira G1 Gira PoE . - - When planning the system, please observe the technical information network planning the device documentation. flush-mounted power supply unit): 168 47 - - Gira (without flush- mounted power supply unit): 168 15 - - Mounting height: 1500 - Notes - - Suitable for indoor use only.001, 5.004, 7.5 higher. Dimming RGB, RGBW, and Tunable White), blind and roller shutter control, value transmitter, and scene auxiliary unit.g.001, 13. - - Can used home station connection with the DCS-IP gateway. - - Ring tone can selected from choice melodies. - - Status display, display date and time, display indoor and outdoor temperature. - - Installation performed deep device box (an electronics box is recommended for LAN connection).xxx, 12. - - When used Gira HomeServer client, the Gira G1's temperature sensor module not supported. When used client, the KNX room operating device features are not available. - - Integrated speaker. - - Using the timers requires either internet connection NTP time server KNX clock (e. Gira can also used client for the following systems/ servers (requires firmware update): - - HomeServer Client - - eNet Client - - Client Technical data Power consumption - - Maximum: W - - Typical: W - - Minimum: W Display - - Type: TFT - - Size: 15.7 M - - Resolution: 480 800 (WVGA), 155 ppi - - Brightness: 350 cd/m² - - Contrast ratio: 1:500 - - Viewing angle: 80° all around Proximity sensor - - Range: max. touch sensor Komfort. - - Operating modes: Comfort, standby, night, and frost heat protection with their own temperature setpoint values (for heating and/or cooling). Several Gira units can operated one Gira KNX router (firmware version and later). For use in the KNX system and Gira door communication system, client. - - 150 functions (six function folders rooms with 25 functions each). - - Switching the ringtone and off. - - Room temperature controller auxiliary unit for controlling air conditioning systems (fan coil) conjunction with KNX gateway for air conditioning systems.010, 6. - - Internal calls. For this purpose the Gira KNX router (firmware version and later) specially equipped with the additional function "Reliable data communication". unit PS Gira electrical installation systems Price system (PS) 14: reduced discount Gira HomeServer Gira FacilityServer The Gira multi-functional room operating device for visualising and operating variety building functions. - - heating clock seven-day timer with switching times. - - Communication with the KNX installation exclusively via the KNXnet/IP standard. - - Recommended mounting height: 150 above floor. - - Commissioning the KNX system from ETS 5.3 (6”) - - Number colours: 16. - - Connection and communication are via LAN WLAN, depending the variant. For details the exact scope functions, please refer the Gira online catalogue and the device's technical documentation. - - Hardware from index status I08 prepared for KNX Secure (additional firmware update required).001, 8. Several Gira units can operated one KNX router. The GPA available free charge the Gira download area. - - KNX router must used connect the Gira PoE the KNX installation. - - 125 seven-day timer with switching times each. - - order ensure reliable communication via WLAN, Gira KNX IP router (firmware version and later) required connect the Gira 230 the KNX installation.g. - - The Gira Project Assistant (GPA) required for firmware updates. Properties video home station - - Camera changeover: specific selection connected colour cameras. - - Control the door opener. Gira weather station Plus 2074 00). Potential applications and combinations - - multi-functional room operating device, the Gira offers the following functions and function combinations: - - KNX room operating device - - Home station video - - Integrates Internet services client for the following systems/ servers HomeServer eNet Alarm Connect security system Properties KNX room operating device - - Intuitive user interface that can adapted the end user. unit Specifications Order No. - - Integrated microphone with echo compensation