Poznámky redaktora
-
- For operation without neutral conductor, the minimum load
for light bulbs, halogen lamps, Gira Tronic transformers,
and wound transformers increases W.
-
- the ambient temperature higher than °C, the
connected load must reduced.
-
- Electronic excess-temperature protection. unit PS
Price system (PS) 14: reduced discount Gira electrical installation systems
Easy
Order
System 55, 420 W/VA
cream white glossy 238501 2385 02
pure white glossy 238503 2385 02
pure white matt 238527 2385 02
anthracite 238528 2385 02
colour aluminium 238526 2385 02
stainless steel 2385600 2385 600 02
COptional accessories
Auxiliary unit
S2000 aux. 100 m
Installation depth: mm
Connections
-
- Single-wire: max.
Technical data
Rated voltage: 230 50/60 Hz
Standby: max.5 mm²
Ambient temperature: +45 °C
Notes
-
- general, operating the dimmer without connecting a
neutral conductor possible, although some LED and CFLi
light sources require the neutral conductor connection to
prevent flickering. mm²
-
- Fine-wire without ferrule: max.
-
- Operation with and without neutral conductor connection. 100 m
-
- Load: max.33
Dimming Easy Order
Specifications Order No.unit 2-wire 0333 D280
System 2000
auxillary line, complete with cover D34
S2000 aux.
Successor item: System 3000 universal LED
dimming insert Komfort 5401 00
System 2000 universal LED dimming insert
(pushbutton dimmer), including cover
. Available until 12/2019. unit Specifications Order No. mm²
-
- Fine-wire with ferrule: max.
-
- Electronic short-circuit protection.
More information
Technical information 638
Dimming
D Discontinued item.
-
- Switch-on brightness can saved permanently.5 W
Connected load °C
-
- LED lamps (leading
edge):
typ.
-
- Connecting auxiliary units possible. 2.unit 3-wire 0335 D281
Power boosters
Features
-
- Universal LED dimming insert for switching and dimming of
light bulbs, halogen lamps, electronic transformers for
halogen LED lamps, dimmable inductive transformers for
halogen LED lamps, LED compact fluorescent
lamps.
-
- Minimum brightness can set.
-
- Bulb-saving switch-on.
-
- Electronic transformers and ballast devices for LED lamps
can operated with the dimming procedure stated the
manufacturer.
-
- Display the selected operating mode using LED. 100 W
-
- Light bulbs: 420 W
-
- halogen lamps: 420 W
-
- Gira tronic transformers: 420 W
-
- electronic transformer
with NV-LED:
typically 100 W
-
- Wound transformer: 420 VA
-
- Wound transformer with
NV-LED:
typically 100 VA
Auxiliary inputs
-
- Non-illuminated
mechanical buttons:
unlimited
-
- Auxiliary insert, 2-wire: unlimited
-
- Auxiliary insert, 3-wire: 5
Cable length
-
- Auxiliary unit: max. 100 W
-
- LED lamps (trailing
edge):
typically 200 W
-
- Compact fluorescent
lamp:
typ. 0.
-
- combination with power boosters, not hook HV-LED
or compact fluorescent lamps.
-
- Automatic manual setting dimming principle according
to load (leading trailing edge)