Basic Electrical Installation Work

| Kategorie: Kniha  |

Strana 318 z 399

Jak získat tento dokument?






Poznámky redaktora
26 and not allowed spiral off, which will cause the cable twist.2, 522. Since PVC conduit insula- tor cannot used the CPC and separate earth conductor must be run every outlet. . The spring pushed into the conduit the point the intended bend and the conduit then bent over the knee. Spacer bar saddle Wall Conduit set out to enter box at right angles Coupling Male bush Metal box Fixing surface Conduit Flange coupling Lead washer Male bush FIGURE 14.8.2).3). 14. Where luminaires are suspended from PVC conduit boxes, precautions must taken ensure that the lamp does not raise the box temperature that the mass the luminaire supported by each box does not exceed the maximum recommended the manufac- turer (IEE Regulations 522.1 and 522. 14. When drawing cables into conduit they must first run off the cable drum. The conduit size and range fit- tings are the same those available for metal conduit.5.Electrical installations and wiring systems 307 Metal conduits are threaded with stocks and dies and bent using spe- cial bending machines.8. The spring ensures that the conduit keeps its circular shape. circuits must contain phase and neutral conductors the same conduit prevent eddy currents flow- ing, which would result the metal conduit becoming hot (Regulations 521. All conduit installations must erected first before any wiring installed (IEE Regulation 522.11).2).25 Terminating conduits. The radius all bends conduit must not cause the cables suffer damage, and therefore the minimum radius bends given Table the Site Guide applies (IEE Regulation 522. Any unused conduit-box entries should blanked off and all boxes covered with box lid, fitting acces- sory provide complete enclosure the conduit system.8. PVC conduit can bent hand using bending spring the same diameter the inside the conduit. PVC conduit most often joined placing the end the conduit into the appropriate fitting and fixing with PVC solvent adhesive.25. That is, the drum must rotated shown Fig. cold weather, little warmth applied the point of the intended bend often helps achieve more successful bend. Metal conduits containing a. The metal conduit also utilized the CPC and, therefore, all connections must screwed tightly and all burrs removed that cables will not damaged they are drawn into the conduit. The advantages PVC conduit system are that may installed much more quickly than steel conduit and non-corrosive, but does not have the mechanical strength steel conduit. not suitable for installations subjected tempera- tures below 25°C above 60°C. All conduits should terminate box fitting and meet the boxes fittings at right angles, shown Fig. PVC conduit also expands much more than metal conduit and long runs require expansion coupling to allow for conduit movement and help prevent distortion during tem- perature changes. PVC CONDUIT PVC conduit used typical electrical installations heavy gauge standard impact tube manufactured 4607.8.1 and 522.c. Conduit runs should separate from other services, unless intentionally bonded, to prevent arcing occurring from faulty circuit within the conduit, which might cause the pipe another service become punctured