com
Number terminals 15, 25, 37, 50
Nominal current 1)
Operating voltage 125V acc.118 www.
Connectors with other connection types may show differing results.
6
5
4
3
2
1
0
0 100 120 140
Current load curve 3)
Ambient temperature [°C]
Operating
current
[A]
* Testing procedure for metallic communication cables part 4-5:
Electromagnetic compatibility (EMC) transition resistance screening attenuation
Test installation with absorbing clamp
Gradient Shielded cable without connector
Gradient Inotec DG09MSX
Gradient Inotec DG09MSBS
Gradient Inotec DG09MS
Gradient Full-metal hood, benchmark
Gradient Metallized plastic hood
Gradient Plastic hood with metal inserts
Screening attenuation according DIN IEC 62153-4-5*
Vector
Network
Analyzer
Port 1
indicator line (l=7m)
indicator line (l=7m)
termination
resistance
absorber
clamp
test item
measuring line
Port 2
50 Ohm
Screening effectiveness Inotec full-metal hoods benchmark
Technical information about Inotec connectors and contacts
0
7
6
5
4
3
2
1
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
dB
10 100 1000
MHz
Protection against radiation interferences
.A
Contact resistance mΩ
Test voltage 1000 eff
Clearance and creepage distance mm
Insulation resistance 1011
Ω
Temperature range -55°C +125°C
Mating cycles 500 200 2)
Insulating body PBTP, parts
Flammability self-extinguishing
acc. to
VDE 0110 Gr. V-0
Shells Steel, over Ni
Contacts turned, Cu-alloy
Surface over Ni
1) According the current load curve shown the graph
2) Corresponding the quality classes according DIN 652
3) The information refers test specimens with hand soldered connections.inotec-electronics