56 Write Event K5
Different events include for
signalling with “Event” is
selected
0 65535, Bit mask
see separate
description. 0
57 Write Event K6
Different events include for
signalling with “Event” is
selected
0 65535, Bit mask
see separate
description. 7
58 Write Event V7
Different events include for
signalling with “Event” is
selected
0 65535, Bit mask
see separate
description. 1=No, 2=2, 3=3 1
63 Write Start Ramp1 1st sequence, time for start ramp -120 Sec 10
64 Write Init Volt1
1st sequence, initial voltage for start
ramp 30
65 Write Curr Lim1 1st sequence, current limit 70= 2,0 7,0 xle 4
66 Write 1st Set 1st sequence, motor rated current 3000 (*) Amp
Individua
l
67 Write Start Ramp2 2nd sequence, time for start ramp -120 Sec 10
68 Write Init Volt2
2nd sequence, initial voltage for start
ramp 30
69 Write Curr Lim2 2nd sequence, current limit 2,0 7,0 xle 40
70 Write 2nd Set 2nd sequence, motor rated current 3000 (*) Amp
Individua
l
71 Write Start Ramp3 3rd sequence, time for start ramp -120 Sec 10
72 Write Init Volt3
3rd sequence, initial voltage for start
ramp 30
73 Write Curr Lim3 3rd sequence, current limit 2,0 7,0 xle 40
74 Write 3rd SetIe 3rd sequence, motor rated current 3000 (*) Amp
Individua
l
75 Read Language Language use display
1=US/UK, 2=FI,
3=SE, 4=PT, 5=NL,
6=IT, 7=FR, 8=ES,
Individua
l
1SFC132043M0201. Type operation for frequency fault 0=Stop-M, 1=Stop-A 0
47 Write Temp Op
Type operation for heat sink over
temperature fault 0=Stop-M, 1=Stop-A 0
48 Write SCR Op
Type operation for thyristor short
circuit fault 0=Stop-M, 1=Stop-A 0
49 Read In0 Function programmable input In0
0=None, 1=Reset,
2=Enable, 3=Jog,
4=DOL-on, 5=Start2,
6=FB-Dis 1
50 Read In1 Function programmable input In1
0=None, 1=Reset,
2=Enable, 3=Jog,
4=DOL-on, 5=Start2,
6=FB-Dis 1
51 Write Relay K4
Function programmable relay output
K4
0=Run, 1=TOR,
2=Event 0
52 Write Relay K5
Function programmable relay output
K5
0=Run, 1=TOR,
2=Event 1
53 Write Relay K6
Function programmable relay output
K6
0=Run, 1=TOR,
2=Event 2
54 Write Outp V7
Function programmable software
output V7
0=Run, 1=TOR,
2=Event 2
55 Write Event K4
Different events include for
signalling with “Event” is
selected
0 65535, Bit mask
see separate
description.Type Parameter Description Range Unit Default
39 Write Warn I=Low Low current warning 0=No, 1=Yes 0
40 Write I=L Lev Trip level for low current warning 0,4 1,0 xle 8
41 Write Warn Overload warning 0=No, 1=Yes 0
42 Write Lev Trip level for overload warning 90
43 Write Warn SCR Thyristor overload warning 0=No, 1=Yes 0
44 Write Loss Type operation for phase loss fault 0=Stop-M, 1=Stop-A 0
45 Write Fault Type operation for fieldbus fault 0=Stop-M, 1=Stop-A 0
46 Write Freq Op. 7
59 Read Fieldb Ctrl Control the softstarter with fieldbus 0=No, 1=Yes 0
60 Read Fieldb Type Type fieldbus 0=AS-Int, 1=Other 1
61 Read Fieldb Addr Fieldbus address 1000 0
62 Write Seq
Number sequences for sequence
start