ABB Softstartéry - komunikace (EN)

| Kategorie: Leták / Datasheet  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 130 z 225







Poznámky redaktora
Type operation for frequency fault 0=Stop-M, 1=Stop-A 0 47 Write Temp Op Type operation for heat sink over temperature fault 0=Stop-M, 1=Stop-A 0 48 Write SCR Op Type operation for thyristor short circuit fault 0=Stop-M, 1=Stop-A 0 49 Read In0 Function programmable input In0 0=None, 1=Reset, 2=Enable, 3=Jog, 4=DOL-on, 5=Start2, 6=FB-Dis 1 50 Read In1 Function programmable input In1 0=None, 1=Reset, 2=Enable, 3=Jog, 4=DOL-on, 5=Start2, 6=FB-Dis 1 51 Write Relay K4 Function programmable relay output K4 0=Run, 1=TOR, 2=Event 0 52 Write Relay K5 Function programmable relay output K5 0=Run, 1=TOR, 2=Event 1 53 Write Relay K6 Function programmable relay output K6 0=Run, 1=TOR, 2=Event 2 54 Write Outp V7 Function programmable software output V7 0=Run, 1=TOR, 2=Event 2 55 Write Event K4 Different events include for signalling with “Event” is selected 0 65535, Bit mask see separate description. 7 59 Read Fieldb Ctrl Control the softstarter with fieldbus 0=No, 1=Yes 0 60 Read Fieldb Type Type fieldbus 0=AS-Int, 1=Other 1 61 Read Fieldb Addr Fieldbus address 1000 0 62 Write Seq Number sequences for sequence start. 0 57 Write Event K6 Different events include for signalling with “Event” is selected 0 65535, Bit mask see separate description. 0 56 Write Event K5 Different events include for signalling with “Event” is selected 0 65535, Bit mask see separate description.Param. 7 58 Write Event V7 Different events include for signalling with “Event” is selected 0 65535, Bit mask see separate description. No Word No Type Parameter Description Range Unit Default 38 Write I=H Lev Trip level for high current warning 0,5 5,0 xle 12 39 Write Warn I=Low Low current warning 0=No, 1=Yes 0 40 Write I=L Lev Trip level for low current warning 0,4 1,0 xle 8 41 Write Warn Overload warning 0=No, 1=Yes 0 42 Write Lev Trip level for overload warning 90 43 Write Warn SCR Thyristor overload warning 0=No, 1=Yes 0 44 Write Loss Type operation for phase loss fault 0=Stop-M, 1=Stop-A 0 45 Write Fault Type operation for fieldbus fault 0=Stop-M, 1=Stop-A 0 46 Write Freq Op. 1=No, 2=2, 3=3 1 63 Write Start Rampl 1st sequence, time for start ramp -120 Sec 10 64 Write Init Voltl 1st sequence, initial voltage for start ramp 30 65 Write Curr Liml 1st sequence, current limit 70= 2,0 7,0 xle 4 66 Write 1st Set 1st sequence, motor rated current 3000 (*) Amp Individual 67 Write Start Ramp2 2nd sequence, time for start ramp -120 Sec 10 68 Write Init Volt2 2nd sequence, initial voltage for start ramp 30 69 Write Curr Lim2 2nd sequence, current limit 2,0 7,0 xle 40 70 Write 2nd Set 2nd sequence, motor rated current 3000 (*) Amp Individual 71 Write Start Ramp3 3rd sequence, time for start ramp -120 Sec 10 72 Write Init Volt3 3rd sequence, initial voltage for start ramp 30 73 Write Curr Lim3 3rd sequence, current limit 2,0 7,0 xle 40 74 Write 3rd Set 3rd sequence, motor rated current 3000 (*) Amp Individual 75 Read Language Language use display 1=US/UK, 2=FI, 3=SE, 4=PT, 5=NL, 6=IT, 7=FR, 8=ES, 9=DE, 10=CN, Individual 1SFC132046M0201