ABB Softstartéry - komunikace (EN)

| Kategorie: Leták / Datasheet  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 131 z 225







Poznámky redaktora
Param. No Word No Type Parameter Description Range Unit Default 11=RU, 12=TR, 13=PL 76 Read Dummy Hidden (Not used) 0 77 Read LCD Auto Off Hidden (Time for display automatic turn off) 255 Minutes 15 78 Read Password Hidden (Password for display) 0=No, 255=1- 255 0 79 Read Date Type Type date presentation 0=IS0 1=CE 2=US 0 80 Read Date Year Year 1901 2038 Individual 81 Read Date Month Month Individual 82 Read Date Day Day Individual 83 Read Time Hour Hour Individual 84 Read Time Min Minutes Individual 85 Read Port Ctrl Hidden (Serial port control) 0=No, 1=Yes 0 86 Read Port Addrl Hidden (Address service port 1st group) 255 192 87 Read Port Addr2 Hidden (Address service port 2nd group) 255 168 88 Read Port Addr3 Hidden (Address service port 3rd group) 255 0 89 Read Port Addr4 Hidden (Address service port 4th group) 255 2 90 Read Ratio Hidden (Ratio current transformers) 2500 Individual 91 Read Int ByPass Hidden (Built by-pass contactor) 0=No, 1=Yes 0 for all PST 1 for all PSTB 92 Read ByPass AC3 Hidden (AC3 value built by-pass contactor) 2500 Amp Individual 93 Read SOP1 Hidden (Thyristor Parameter 120 0,7 1,2 Individual 94 Read SOP2 Hidden (Thyristor Parameter 2) 5 2000 0,05 - 20,00 Individual 95 Read SOP3 Hidden (Thyristor Parameter 3) 11 1200 = 0,011 1,200 Individual 96 Read SOP4 Hidden (Thyristor Parameter 150 1,0 15,0 Individual 97 Write Closed Op Type operation for by-pass doesn’t open 0=Stop-M, 1=Stop-A 0 98 Write Open Op Type operation for by-pass doesn’t close 0=Stop-M, 1=Stop-A 0 99 Read Dummy Hidden (Not used) 0 100 Read FCODE1 Hidden (Factory code 0-10 0 101 Read FCODE2 Hidden (Factory code 0-10 0 102 Read FCODE3 Hidden (Factory code 0-10 0 103 Read FCODE4 Hidden (Factory code 0-10 0 104 Read FCODE5 Hidden (Factory code 0-100 0 105 Read FCODE6 Hidden (Factory code 0-100 0 106 Read PST(B) PST(B) size 1-2500 Amp Individual 107 Read FCODE7 Hidden (Factory code 0=No, 1=Yes 1 108 Read FCODE8 Hidden (Factory code 0=No, 1=Yes 1 109 Read FCODE9 Hidden (Factory code 0=No, 1=Yes 1 110 Read FCODElO Hidden (Factory code 10) 0-25 14 111 Write Lim Time Time for dual current limit 0-120 Sec 0 112 Write Lim Lev Level for dual current limit 20-70 2,0-7,0 xle 40 113 Write Auto Dis Fieldbus autodisable 0=No, 1=Yes 0 114 Write Start Mode Start mode Volt, Torque Volt 115 Write Stop Mode Stop mode Volt, Torque Volt 116 Write Torque Limit Torque limit 20-200 150 117 Write Tune T-Ctrl Tune Torque control 30-300 100 118 Read FCODE11 Hidden (Factory code 11) 1-1000 0,01-10,00 0,40 119 Read FCODE12 Hidden (Factory code 12) 1-10000 0,001­ 10,000 0,040 1SFC132046M0201