3 Enable Enable, this bit must set for running the motor
4 Jog Perform Jog when signal set. Start1 sequence
start.
2 Reset Events Reset signal for possible events.
7 Start3 (3rdpar
set Seq.start)
Start2 sequence start.
6 Start2 (2ndpar
set Seq.
1 (0) Time
synchronisation
Time synchronisation signal that used synchronise
the local real time clock with the time given an
analogue input telegram the softstarter.start)
Start3 sequence start.
Word in
output
data area
Binary
output
byte
Bit Data Description
0 Start (1stpar set
if Seq.
5 DOL start Perform DOL start when signal set.Binary output telegram
From PLC Softstarter.
9 (1) Reset active
diagnostics
When set “1” this will reset the fieldbus diagnostic
area
10 (2) Spare
11 (3) Spare
12 (4) Spare
13 (5) Spare
14 (6) Spare
15 (7) Spare
1SFC132012M0201.start)
Commence start when signal set.
1 Stop Commence stop when signal negated. the signal is
“1” and there difference between the times the local
real time clock synchronised