ABB Softstartéry - komunikace (EN)

| Kategorie: Leták / Datasheet  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 22 z 225







Poznámky redaktora
2,0 7,0 xIe 8 Read/Write Kick Start Selection Kick start No, Yes 9 Read/Write Kick Level Level Kick start selected 100 % 10 Read/Write Kick Time Time for Kick start selected 0,1 1,5 Sec 11 Read/Write Start Range Selectable range for start ramp 1-30, 1-120 Sec 12 Read/Write Stop Range Selectable range for stop ramp 0-30, 0-120 Sec 13 Read/Write Overload Overload protection No, Normal, Dual 14 Read/Write Class Overload Class 10A, 10, 20, 30 15 Read/Write Class Overload Class, Dual type, Start Class 10A, 10, 20, 30 16 Read/Write Class Overload Class, Dual type, Run Class 10A, 10, 20, 30 17 Read/Write Type operation for overload protection Stop-M, Stop-A, Ind 18 Read/Write Locked Rotor Locked rotor protection No, Yes 19 Read/Write Lock Lev Trip level for locked rotor protection ,0 8, - ,5 <o xIe 20 Read/Write Lock Time Trip time for locked rotor protection 0,2 10,0 Sec 21 Read/Write Lock Type operation for locked rotor protection Stop-M, Stop-A, Ind 22 Read/Write Underload Underload protection No, Yes 23 Read/Write Underl Lev Trip level for Underload protection ,8 0, - ,4 <o xIe 24 Read/Write Underl Time Trip time for Underload protection Sec 25 Read/Write Underl Type operation for Underload protection Stop-M, Stop-A, Ind 26 Read/Write Phase Imb Phase imbalance protection No, Yes 27 Read/Write Imb Lev Trip level for phase imbalance protection % 28 Read/Write Imb Op Type operation for phase imbalance protection Stop-M, Stop-A, Ind 29 Read/Write High High current protection No, Yes 30 Read/Write High Type operation for high current protection Stop-M, Stop-A, Ind 31 Read/Write Phase Rev Phase reversal protection No, Yes 32 Read/Write Rev Op Type operation for phase reversal protection Stop-M, Stop-A, Ind 33 Read/Write PTC PTC protection No, Yes 34 Read/Write PTC Type operation for PTC protection Stop-M, Stop-A, Ind 35 Read/Write Ext ByPass External By-pass contactor used No, Yes 36 Read Dummy Spare parameter 0 37 Read/Write Warn I=High High current warning No, Yes 38 Read/Write I=H Lev Trip level for high current warning ,0 5 - ,5 o" xIe 39 Read/Write Warn I=Low Low current warning No, Yes 40 Read/Write I=L Lev Trip level for low current warning 0,4 1,0 xIe 41 Read/Write Warn Overload warning No, Yes 42 Read/Write Lev Trip level for overload warning % 43 Read/Write Warn SCR OL Thyristor overload warning No, Yes 44 Read/Write Loss Type operation for phase loss fault Stop-M, Stop-A 45 Read/Write Fault Type operation for fieldbus fault Stop-M, Stop-A 1SFC132013M0201 10 .Parameters Profibus V1 For this implementation all parameter values (both binary and analogue) are represented bits. 100 % 7 Read/Write Current Lim Level the current limit. No Type Parameter Description Range Unit 1 Read/Write Setting Setting current 3000 (*) Amp 2 Read/Write Start Ramp Time for start ramp 120 Sec 3 Read/Write Stop Ramp Time for stop ramp 120 Sec 4 Read/Write Init Volt Initial voltage for start ramp % 5 Read/Write End Volt End voltage for stop ramp % 6 Read/Write Step Down Voltage value which the softstarter shall step down stop and where shall commence the stop ramp