Poznámky redaktora
Type Parameter Description Range Unit 72 Read/Write Init Volt3 3rd sequence, initial voltage for start ramp % 73 Read/Write Curr Lim3 3rd sequence, current limit 2,0 7,0 xle 74 Read/Write 3rd SetIe 3rd sequence, motor rated current 3000 (*) Amp 75 Read Language Language use display US/UK, FI, SE, PT, NL, IT, FR, ES, DE, CN, RU, TR, PL 76 Read Dummy Hidden (Not used) 0 77 Read LCD Auto Off Hidden (Time for display automatic turn off) 255 Sec 78 Read Password Hidden (Password for display) 255 79 Read Date Type Type date presentation ISO US 80 Read Date Year Year 1901 2038 81 Read Date Month Month 12 82 Read Date Day Day 31 83 Read Time Hour Hour 23 84 Read Time Min Minutes 59 85 Read Port Ctrl Hidden (Serial port control) No, Yes 86 Read Port Addrl Hidden (Address service port 1st group) 255 87 Read Port Addr2 Hidden (Address service port 2ndgroup) 255 88 Read Port Addr3 Hidden (Address service port 3rdgroup) 255 89 Read Port Addr4 Hidden (Address service port 4thgroup) 255 90 Read Ratio Hidden (Ratio current transformers) 2500 91 Read Int ByPass Hidden (Built by-pass contactor) No, Yes 92 Read ByPass AC3 Hidden (AC3 value built by-pass contactor) 2500 Amp 93 Read SOP1 Hidden (Thyristor Parameter 0,7 1,2 94 Read SOP2 Hidden (Thyristor Parameter 0,05 20,00 95 Read SOP3 Hidden (Thyristor Parameter 0,011 1,200 96 Read SOP4 Hidden (Thyristor Parameter 1,0 20,0 97 Read/Write Closed Type operation for by-pass doesn’t open Stop-M, Stop-A 98 Read/Write Open Type operation for by-pass doesn’t close Stop-M, Stop-A 99 Read Dummy Hidden (Not used) 0 100 Read FCODE1 Hidden (Factory code 0-10 101 Read FCODE2 Hidden (Factory code 0-10 102 Read FCODE3 Hidden (Factory code 0-10 103 Read FCODE4 Hidden (Factory code 0-10 104 Read FCODE5 Hidden (Factory code 0-100 105 Read FCODE6 Hidden (Factory code 0-100 106 Read PST(B) PST(B) size 1-2500 Amp 107 Read FCODE7 Hidden (Factory code Yes, No 108 Read FCODE8 Hidden (Factory code Yes, No 109 Read FCODE9 Hidden (Factory code Yes, No 110 Read FCODE10 Hidden (Factory code 10) 0-25 111 Read/Write Lim Time Time for dual current limit 0-120 Sec 112 Read/Write Lim Lev Level for dual current limit 2,0-7,0 xle 113 Read/Write Auto Dis Fieldbus autodisable Yes, No 114 Read/Write Start Mode Start mode Volt, Torque 115 Read/Write Stop Mode Stop mode Volt, Torque 116 Read/Write Torque Limit Torque limit 20-200 % 117 Read/Write Tune T-Ctrl Tune Torque control 30-300 % 118 Read FCODE11 Hidden (Factory code 11) 0,01-10,00 119 Read FCODE12 Hidden (Factory code 12) 0,001-10,000 120 Read FCODE13 Hidden (Factory code 13) 0,001-1,000 121 Read FCODE14 Hidden (Factory code 14) 0,001-1,000 1SFC132044M0201 12