Voltage fluctuations Testing performed per EN 61000-4-11 61000-4-29 Test values per EN 61131-2 (Zone B) Test values per EN 61000-6-2 AC mains inputs -15% +10% Test duration per minutes Criteria A - DC mains inputs -15% +20% Test duration per minutes Criteria A - 98 Smart Camera Smart Sensor User's manual 1.5 periods (50/60 Hz) 1) 20 attempts Criteria A 0% residual voltage 1 period (50/60 Hz) 1) 3 attempts Criteria B DC mains inputs residual voltage ≥10 (PS2) 2) 20 attempts Criteria A - 1) Mains frequency per manufacturer data 2) Use B&R power supply unit guarantees that these requirements are met.23 .International and national certifications Voltage dips Testing performed per EN 61000-4-11 Test values per EN 61131-2 (Zone B) Test values per EN 61000-6-2 0% residual voltage 250/300 periods (50/60 Hz) 1) 20 attempts Criteria C 40% residual voltage 10/12 periods (50/60 Hz) 1) 20 attempts Criteria C AC mains inputs 70% residual voltage 25/30 periods (50/60 Hz) 1) 20 attempts Criteria C 1) Mains frequency per manufacturer data Short-term interruptions Testing performed per EN 61000-4-11 61000-4-29 Test values per EN 61131-2 (Zone B) Test values per EN 61000-6-2 AC mains inputs residual voltage 0