23 99 .3 Emission requirements Test Testing performed per standard: Limit values per standard EN 61131-2: Product standard Programmable controllers Emissions related lines EN 55011 55032 EN 55016-2-1 61000-6-4: Generic standards - Emission standard for industrial environments EN 61131-2: Product standard Programmable controllers Radiated emissions EN 55011 55032 EN 55016-2-3 61000-6-4: Generic standards - Emission standard for industrial environments Emissions related lines Testing performed per EN 55011 55032 55016-2-1 Limit values per EN 61131-2 (Zone B) Limit values per EN 61000-6-4 150 500 kHz 79 (μV) quasi-peak value 66 (μV) mean value AC mains connection 150 kHz MHz 500 kHz MHz 73 (μV) quasi-peak value 60 (μV) mean value - 150 500 kHz 97 (µV) quasi-peak value 53 (µA) quasi-peak value 84 (µV) mean value 40 (µA) mean value Telecommunications network connection 150 kHz MHz - 500 kHz MHz 87 (µV) quasi-peak value 43 (µA) quasi-peak value 74 (µV) mean value 30 (µA) mean value Radiated emissions Testing performed per EN 55011 55032 55016-2-3 Limit values per EN 61131-2 (Zone B) Limit values per EN 61000-6-4 30 230 MHz 40 (μV) quasi-peak value Electric field Measured from m 30 MHz GHz 230 MHz GHz 47 (μV) quasi-peak value - GHz 76 (µV/m) peak value 56 (µV/m) mean value Electric field Measured from m 1 GHz 1) - GHz 80 (µV/m) peak value 60 (µV/m) mean value 1) Depends the highest internal frequency Smart Camera Smart Sensor User's manual 1.2.International and national certifications 11