23 99
.3 Emission requirements
Test Testing performed per standard: Limit values per standard
EN 61131-2: Product standard Programmable
controllers
Emissions related lines
EN 55011 55032
EN 55016-2-1 61000-6-4: Generic standards -
Emission standard for industrial environments
EN 61131-2: Product standard Programmable
controllers
Radiated emissions
EN 55011 55032
EN 55016-2-3 61000-6-4: Generic standards -
Emission standard for industrial environments
Emissions related lines
Testing performed per
EN 55011 55032 55016-2-1
Limit values per
EN 61131-2 (Zone B)
Limit values per
EN 61000-6-4
150 500 kHz
79 (μV) quasi-peak value
66 (μV) mean value
AC mains connection
150 kHz MHz
500 kHz MHz
73 (μV) quasi-peak value
60 (μV) mean value
- 150 500 kHz
97 (µV) quasi-peak value
53 (µA) quasi-peak value
84 (µV) mean value
40 (µA) mean value
Telecommunications network connection
150 kHz MHz
- 500 kHz MHz
87 (µV) quasi-peak value
43 (µA) quasi-peak value
74 (µV) mean value
30 (µA) mean value
Radiated emissions
Testing performed per
EN 55011 55032 55016-2-3
Limit values per
EN 61131-2 (Zone B)
Limit values per
EN 61000-6-4
30 230 MHz
40 (μV) quasi-peak value
Electric field Measured from m
30 MHz GHz
230 MHz GHz
47 (μV) quasi-peak value
- GHz
76 (µV/m) peak value
56 (µV/m) mean value
Electric field Measured from m
1 GHz 1)
- GHz
80 (µV/m) peak value
60 (µV/m) mean value
1) Depends the highest internal frequency
Smart Camera Smart Sensor User's manual 1.2.International and national certifications
11