ABB Softstartéry - komunikace (EN)

| Kategorie: Leták / Datasheet  | Tento dokument chci!

Vydal: ABB s.r.o, ELSYNN Autor: ABB ELSYnn

Strana 65 z 225







Poznámky redaktora
1 (0) Time synchronisation Time synchronisation signal that used synchronise the local real time clock with the time given an analogue input telegram the softstarter. 5 DOL start Perform DOL start when signal set.Binary output telegram From PLC Softstarter. 2 Reset Events Reset signal for possible events.start) Start3 sequence start.start) Commence start when signal set. the signal is “1” and there difference between the times the local real time clock synchronised. Startl sequence start. 9 (1) Reset active diagnostics When set “1” this will reset the fieldbus diagnostic area 10 (2) Spare 11 (3) Spare 12 (4) Spare 13 (5) Spare 14 (6) Spare 15 (7) Spare 1SFC132013M0201. 6 Start2 (2ndpar set Seq. Word in output data area Binary output byte Bit Data Description 0 Start (1stpar set if Seq. 7 Start3 (3rdpar set Seq.start) Start2 sequence start. 1 Stop Commence stop when signal negated. 3 Enable Enable, this bit must set for running the motor 4 Jog Perform Jog when signal set