Poznámky redaktora
Before the Profibus fieldbus can taken operation following parameters must beset the softstarter:
■ Parameter Fieldbus Ctrl set Yes
■ Parameter Fieldbus Type set other
■ Parameter Fieldbus Addr set free communication address.
For technical data and descriptions the Profibus fieldbus plug, see document 2CDC192001D0202,
available www.
• Switchingfrom one type control another (fieldbus control hardwire control)
• Re-programming the programmable inputs
• Reset all Settings (programmable input set Enable)
1SFC132013M0201.
See chapter “Setting and configuration” the installation manual for programming the inputs outputs.
ACaution!
The motor may start unexpectedly there start signalpresent when doing any the actions listed below. Through the fieldbus possible start and stop the motor, perform
jog, sequence start, read out currents and frequency, achieve information about protections, warnings, faults and
much more.com/lowvoltage .abb.Profibus V0
The Profibus protocol fieldbus protocol that provides full control and status information the
softstarter well writing parameters