04.
For technical data and descriptions the DeviceNet fieldbus plug, see document 2CDC193001D0203,
available www.
See chapter “Setting and configuration” the installation manual for programming the inputs outputs.com/lowvoltage .abb. Through the fieldbus ispossibleto start and stopthe motor, perform
jog, sequence start, read out currents and frequency, achieve information about protections, warnings, faults and
much more.00 EDS_PST_Rev4_5.05.eds
CU 03.01 and 03.
To the programming the PLC, following EDS files are available:
Softstarter CU-version EDS file
CU 02.03.
• Switchingfrom one type control another (fieldbus control hardwire control)
• Re-programming the programmable inputs
• Reset all Settings (programmable input set Enable)
1SFC132012M0201.
Before the DeviceNet fieldbus can taken operation following parameters must set the softstarter:
■ Parameter Fieldbus Ctrl set Yes
■ Parameter Fieldbus Type set other
■ Parameter Fieldbus Addr set free communication address.eds
ACaution!
The motor may start unexpectedly there start signalpresent when doing any the actions listed below.02 EDS_PST_Rev4_4.DeviceNet
The DeviceNet protocol fieldbus protocol that provides full controland statusinformation the softstarter as
well reading and writing parameters.eds
CU 03.01 EDS_PST_Rev4_0.00