75 2.
Left picture Vertical jumper (2002-492)
Right picture Push-in type jumper bar (2002 Series)
4-conductor through terminal blocks (2002-2609) with
internal commoning can immediately identified via
violet conductor entry.com
.75 mm²
dark gray 2002-172 200 (25)
Push-in type jumper bar; insulated; light gray
2-way 2002-402 25
3-way 2002-403 25
4-way 2002-404 25
5-way 2002-405 25
6-way 2002-406 25
7-way 2002-407 25
8-way 2002-408 25
9-way 2002-409 25
10-way 2002-410 25
Push-in type jumper bar; insulated; light gray
1 2002-433 25
1 2002-434 25
1 2002-435 25
1 2002-436 25
1 2002-437 25
1 2002-438 25
1 2002-439 25
1 2002-440 25
Double-deck vertical jumper; insulated; A
light gray 2002-492 100 (25)
orange 2002-492/000-012
100 (25)
Adjacent jumper for continuous commoning; insulated; IN
25 light gray
2-way 2002-400 25
Double-deck disconnect terminal blocks with pivoting
knife disconnect (2002-2671) can used through ter-
minal blocks the lower deck and disconnect terminal
blocks the upper deck.5 mm²
light gray 2002-171 200 (25)
Insulation stop; pcs/strip; 0.25 mm² “s+f-st”
Push-in termination: 0.
“ Please observe the application notes:
Jumpers, from page 151
Testing accessories, from page 145
Marking, from page 230
“ Approvals and corresponding ratings,
visit www.wago.
Through terminal blocks (2002-2601) feature two indepen-
dent current bars both lower and upper deck, sharing
the same profile disconnect terminal blocks.
The following components may used:
- Disconnect plugs (a: 2002‑401)
- Pluggable diode (b: 2002‑800/1000‑411)
- LED module (2002‑800/1000‑541, illustration)
- Fuse plug (c: 2004‑911)
An end plate for fuse disconnect terminal blocks (shown
in orange, 2002-1092) used for additional protection,
preventing the fuse holder from being opened.
Besides disconnection and measurement, double-deck
carrier terminal blocks (2002-2667) also provide ground
conductor functionality.g.59
a
b
c
www., 2002‑2611/1000‑541 for 12–30 V).75 mm² “s”
and 0. The fuse
cannot replaced until disconnecting the fuse holder
from the power supply.
Carrier terminal blocks (2002‑2661) have the same design
as disconnect terminal blocks.wago.
These terminal blocks can commoned via double-deck
vertical jumpers (2002-492). The fuse holder also available with blown fuse
LED indicator (e.com
Rail-Mount Terminal Blocks, TOPJOB® S
Rail-Mount Terminal Blocks, TOPJOB® S
Accessories; 2002 Series
Appropriate marking systems: WMB/WMB Inline/Marking
Strips
End and intermediate plate; thick
orange 2002-2692 100 (25)
gray 2002-2691 100 (25)
Double-deck marker carrier; pivoting
gray 2002-121 (25)
Insulation stop; pcs/strip; 0.
1 Conductor range: 0.
The same profile allows for commoning with TOPJOB®
S double-deck terminal blocks (upper deck) and with
triple-deck terminal blocks (lower deck).
Double-deck fuse disconnect terminal blocks with pivot-
ing fuse holder (2002-2611, gray) are compatible with dis-
connect, carrier, through and ground conductor terminal
blocks.5 mm²
“insulated ferrules, mm”
2 400 rated voltage
6 rated impulse voltage
3 pollution degree
3 Terminal blocks with blue insulated housing are
suitable for applications.25 0