TOPJOB® S Rail-Mount Terminal Block Systems Edition 2018

| Kategorie: Katalog  |

Vydal: WAGO Elektro spol. s r.o. Autor: EN version

Strana 46 z 268

Jak získat tento dokument?






Poznámky redaktora
Additional through terminal blocks having smaller cross-section may commoned using push-in type jumper bars.14 in 36,9 mm/ 1.5 (25 “f-st”) mm² AWG 0. Finger guard seals unused conductor entry.71 0.79 inch 0.5 mm² “s” and 2.75 in 32,3mm/1. This can be beneficial long conductor runs where voltage drop can problem.44 91,8 mm/3. Commoning may made either direction using the special thin end plate cover the open side. Pack. 4 Terminal blocks with mark are suitable for II applications.472 inch Terminal block width: 0. large conductor can easily con- nected smaller conductors the distribution point. 550 for 2-conductor terminal blocks 550 for 3-conductor terminal blocks 65 jumper “ Please observe the application notes: Separator for e/Ex applications, see page 29 Step-down jumpers, see page 41 Jumpers, from page 149 Testing accessories, from page 143 Marking, from page 230 “ Approvals and corresponding ratings, visit www. Pack. .com Rail-Mount Terminal Blocks, TOPJOB® S Rail-Mount Terminal Blocks, TOPJOB® S TOPJOB® (25 “f-st”) mm²; 2016 Series Through/Ground Conductor/Shield Conductor/Ex Terminal Block Push-in type jumper bar; insulated; light gray 2-way 2016-402 25 3-way 2016-403 25 4-way 2016-404 25 5-way 2016-405 25 Push-in type jumper bar; insulated; light gray 1 2016-433 25 1 2016-434 25 1 2016-435 25 Star point jumper; insulated; terminal block; light gray 1-3-5 2016-405/011-000 25 Step-down jumper; insulated; commons 16/10 mm² (8/10 AWG) 10/6/4/2.45 in www.27in 36,9 mm/ 1.com Step-down jumpers common terminal blocks different sizes, without losing conductor clamping point. Unit Color Item No.45 in 69,8 mm/2.5 mm² “insulated ferrules, mm” 2 800 rated voltage 8 rated impulse voltage 3 pollution degree 3 Terminal blocks with blue insulated housing are suitable for applications.wago.2 mm plain 793-5501 5 Technical Data Technical Data 0.5 mm² (8/10/12/14 AWG); A light gray 2016-499 25 Protective warning marker; with black high-voltage symbol; for terminal blocks yellow 2016-115 100 (25) Finger guard; touch-proof cover protects unused con- ductor entries yellow 2016-100 100 (25) Modular TOPJOB® connector; snaps together; for jumper contact slot gray 2016-511 (25) Test plug adapter; for test plug gray 2009-174 100 (25) Marking strip; plain; wide; reel white 2009-110 1 WMB Multi marking system; white; strips with mar- kers/card; stretchable from 5.wago.61 in 54,3 mm/2.5 mm² “s+f-st”, mm² “f-st”; Push-in termination: 2.79 inch 2-conductor through terminal block 3-conductor through terminal block Color Item No.5 (25 “f-st”) mm² AWG 800 V/8 kV/3 600 800 V/8 kV/3 600 AU IN (90 600 (90 600 A2 Terminal block width: 0.472 inch L 0.71 0. Unit gray 2016-1201 gray 2016-1301 20 blue 2016-1204 blue 2016-1304 20 orange 2016-1202 orange 2016-1302 20 2-conductor ground terminal block 3-conductor ground terminal block green-yellow 2016-1207 green-yellow 2016-1307 20 2-conductor shield terminal block white 2016-1208 20 Accessories; item-specific Accessories; item-specific End and intermediate plate; thick End and intermediate plate; thick orange 2016-1292 100 (25) orange 2016-1392 100 (25) gray 2016-1291 100 (25) gray 2016-1391 100 (25) Ex e/Ex separator; orange; thick 120 209-191 (25) Accessories; 2016 Series Appropriate marking systems: WMB/WMB Inline/Marking Strips 1 Conductor range: 0