TOPJOB S Rail-Mount Terminal Block Systems

| Kategorie: Katalog  | Tento dokument chci!

Vydal: WAGO Elektro spol. s r.o.

Strana 90 z 268







Poznámky redaktora
25 0.. The temperature rise the termi- nal blocks must checked according their application and mounting... The power loss determined according IEC 60947-7- 3/VDE 0611-6 23°C. Due the 6.. Pack. Therefore, such applications, the rated current must reduced neces- sary.75 2.2 0.wago.87 in 57,6 mm/2.244 inch Terminal block width: 6.39 0. More details are available from the manufacturers.25 2.5 mm² conductor cross-section; A L 2009-412 100 (10) L 110 2009-414 100 (10) L 250 2009-416 100 (10) Push-in type jumper bar; insulated; light gray 2-way 2004-402 25 3-way 2004-403 25 4-way 2004-404 25 5-way 2004-405 25 6-way 2004-406 25 7-way 2004-407 25 8-way 2004-408 25 9-way 2004-409 25 10-way 2004-410 25 Push-in type jumper bar; insulated; light gray 1 2004-433 25 1 2004-434 25 1 2004-435 25 1 2004-436 25 1 2004-437 25 1 2004-438 25 1 2004-439 25 1 2004-440 25 When selecting miniature metric fuses, make sure that the maximum power loss listed below not exceeded..27 in 40,8 mm/1.2 width of double-deck terminal blocks with end plates, 2004 Series Push-In Type Jumper Bars must used. Overload and short circuit protection Short circuit protection only Individual argmt.47 inch End plate for fuse terminal blocks; thick orange 2002-992 100 (25) gray 2002-991 100 (25) Insulation stop; pcs/strip; 0.47 inch 0.5 W 2.87 in 57,6 mm/2.6 1.61 in 2002-1911 2002-1911/. Higher ambient temperatures represent an additional impact miniature fuses. Group argmt. 1.25 2.. Unit gray 2002-1911 2002-1911/1000-541 50 30 2002-1911/1000-542 50 120 2002-1911/1000-867 50 230 2002-1911/1000-836 50 Other terminal blocks with the same profile: Other terminal blocks with the same profile: Through 2002‑1901 Page Through 2002‑1901 Page 84 Accessories; 2002 Series Appropriate marking systems: WMB/WMB Inline/Marking Strips 1 Conductor range: 0.com Rail-Mount Terminal Blocks, TOPJOB® S Rail-Mount Terminal Blocks, TOPJOB® S TOPJOB® 2. Leakage current case blown fuse: LED 2 mA Color Item No. “ Approvals and corresponding ratings, visit www.5 mm² “insulated ferrules; mm” 2 250 rated voltage 6 rated impulse voltage 3 pollution degree “ Please observe the application notes: Jumpers, from page 150 Marking, from page 230 “ protective warning marker and insulation stop must applied individually.2 0.5 W Miniature fuses 20 Series Item No.39 0.75 mm² dark gray 2002-172 200 (25) Protective warning marker; with black high-voltage symbol; for terminal blocks yellow 2002-115 100 (25) Push-in type wire jumper; insulated; 1.61 in 72,9 mm/2.25 mm² “s+f-st” Push-in termination: 0. Unit Item No. Fuse terminal blocks www. Individual argmt.5 (4) mm² AWG 250 V/6 kV/3 600 6,3 250 V/6 kV/3 6,3 AU IN 6.6 1. Pack.244 inch L 0.5 (4) mm² AWG 0.5 mm² light gray 2002-171 200 (25) Insulation stop; pcs/strip; 0.6 2.5 2.88 72,9 mm/2.-.5 (4) mm²; 2002 Series Fused Disconnect Terminal Block with Pivoting Fuse Holder and Additional Jumper Slot; for x 20) Miniature Metric Fuses 2-conductor fused disconnect terminal block with piv- oting fuse holder; with additional jumper slot; for 20) mm miniature metric fuse; without blown fuse indication Electrical ratings are given the fuse.3 6.75 mm² “s” and 0.wago.5 W 1. .3 A Terminal block width: 6.27 in 40,8 mm/1.6 2. 2-conductor fused disconnect terminal block with a pivoting fuse holder; with additional jumper slot; for x 20) miniature metric fuse; with blown fuse indication by LED; gray Electrical ratings are given the fuse and blown fuse indication.com Technical Data Technical Data 0. Group argmt