EATON WIRELESS SYSTEM
87
Functions the switching actuator Basic-Mode
RF Push-button: OFF
Remote control: OFF
Binary input:
Mode Both channels: current impulse
Mode Both channels: OFF
Mode Channel current impulse; channel OFF
Mode Channel ON; channel OFF
Room temperature control:Too cold: ON; too warm: OFF
Mains supply restored: Last value
With low batterie: Flashing
Functions the dimming actuator Basic-Mode
RF Push-button: OFF and brighter/darker
Remote control: OFF and brighter/darker
Binary input:
Mode Both channels with push-button and dimming function
Mode Both channels only OFF without brighter/darker function
Mode Channel push-button and dimming function
Channel only OFF without brighter/darker function
Mode Channel and brighter;
Channel OFF and darker
Room temperature control:Too cold: ON; too warm OFF (without dimming)
Mains supply restored: Last value
With low batterie: Flashing
Dimming time: sec
Dimming limits: 100%
Functions the blinds actuator Basic-Mode
RF Push-button: Blinds (up/down with stop slat)
Remote control: Blinds (up/ down with stop slat)
Binary input:
Mode Both channels: automatic sequence control (without slat only stop)
Mode Both channels: automatic sequence control (without slat only stop) Õ
Mode Channel automatic sequence control see mode 1
Channel automatic sequence control see mode 2
Mode Channel and slat stop
Channel down and slat down stop
Room temperature control: Shutters: too cold: open; too warm: close
Operating time: sec