Technical Specifications EATON RF System

| Kategorie: Leták / Datasheet  |

Vydal: xComfort (EATON)

Strana 29 z 95

Jak získat tento dokument?






Poznámky redaktora
EATON SYSTEM 29 Switching Actuator CSAU-01/01-1.0 higher If one the connected devices does not support the Extended Status Messaging format the Actuator will switch back the standard status messaging format.0W-3700.5 45. Failure could result fire hazard or electric shock under extreme external fault condi- tions.5mm² all connections CSAU-01/01-16(IE) Single-wired 2. R ESM Derating 'HUDWLQJ $ $ $ $ $ $ $ ϭϲ/ ϭϲ͕ ϭϲ/ ! CSAU-01/01-16 CSAU-01/01-16I CSAU-01/01-16IE 4 EN60670 ATTENTION! CSAU-01/01-16, CSAU-01/01-16I, CSAU-01/01-16IE: This device must installed inside mounting box (complying EN60670) and behind acce- ssory blank plate that uses least screw fix- ing points secure the mounting box.(I) 0.5mm² L+LA connections Single-wired 1.5 18mm Length connection wires 150mm Approval Printed onto the device Basic Mode support: Local Input mode: Push-button (Mode 1), Switch (Mode 2) Function mode: On/Off, Surge, Push-button, Staircase, Staircase with pre-warning Extended Status Messaging support: Output status OFF, ON, OFF Locked, Locked, Blinking, OFF over temperature Binary input ON, OFF pressed, not pressed Internal device temperature 0-125 °C Current Power load 0.IE 49,5 52,6 18 Technical Specifications Power supply 230VAC, 50Hz Connections CSAU-01/01-10(IE) Single-wired 1.5mm² N+IN connections Power consumption CSAU-01/01-1.0W Load Error Detection status OK, Not OK ATTENTION! Extended Status Messaging supported the following Smart Devices: Room Manager V41a (for output 1-10) higher Smart Home Controller V2.23W CSAU-01/01-1. -25 +70°C Colour the frame Grey, RAL7035 Size the frame HxWxD 49.25W Switching technology Eaton Patented Hybrid switching technology Load switching The device switches via LA CSAU-01/01-10(IE) 230VAC, 50Hz, 10A RLC load CSAU-01/01-16(IE) 230VAC, 50Hz, 16A RLC load Energy Measurement Sensor CSAU-01/01-10(IE) 2300W, accuracy >3W CSAU-01/01-16(IE) 3680W, accuracy >3W Measurement units Energy kWh, Active power W Binary Input voltage Maximum 265V Input contact resistance <10kΩ reliably ON, >50kΩ reliably OFF Voltage difference <1V reliably ON, >3V reliably OFF Internal protection Overvoltage, temperature (load will be disconnected) Pre-protection Power circuit breaker 16A, characteristic C Frequency 868,300 MHz Type transmission Bi-directional, via coded telegrams Indoor range Typically 50m, walls ceiling (depending wall thickness and material !!) Function Assignments 32 Routing Paths 32 Degree protection IP20 Degree soiling 2 Operating temperature +55°C Storage /transportation temp.IE 0.0 higher Ethernet V2. Protect with MCB 16AType B/C according EN60898 .0 higher USB RF-Communication stick V2