Návod na instalaci omezovačů nízkého napětí ALVL

| Kategorie: Leták / Datasheet  | Tento dokument chci!

Vydal: ACER VOLTAGE s.r.o.

Strana 2 z 2







Poznámky redaktora
.Instructions for installing of low-voltage limiters ALVL 60 ALVL 120 1. Such activation corresponds the voltage drop across the varistor. storms. The limiter has installed directly between the elements the protected structures (using two bolts M12) the event its activation has occurred desired equipotential between them. According 50122-1:2011 this type of limiter recommended mainly for the connection between the protected part and return circuit the overhead line zones (or pantograph zones) that may contact with the conductors damaged current collector, then the support structures of pylons which can become live due an insulation failure. CHARACTERISTICS PRODUCT AND BASIC PROPERTIES If overvoltage occurs for longer period of time (milliseconds hours) the thyristors fire limit touch voltage value.com .). soon as the overvoltage condition ends, the thyristors cut off the current flow and the original condition restored. Functional check ALVL Overload the ALVL limiters may lead to a fault one even both thyristors. Before you can perform the control measurement you must disconnect the low voltage limiter.com www. During assembly necessary respect the principles occupational safety and health.o. Check the limiters are not mechanically damaged regular intervals.GENERALRULES FORLIMITERCONNECTION Only the authorized person with an appropriate certification according ČSN EN 50110-1 ed. 2. The ALVL limiters are maintenance free, have high insulation resistance value (kW) and high protection capability..e. FIELD APPLICATION AND PLACE ALVL and ALVL 120 low voltage limiters, recoverable VLD 2. Recommended mounting position vertical bracket up. They are used effectively protect persons, who may come into contact with these parts during lightning strikes case a defect the traction power line. Also check they are not excessively covered by dirt.2022 ALVL* ACER VOLTAGE s.acervoltage. is therefore recommended test the ALVL in regular intervals. The connecting conductors can made with a circular section. During the process the standards must be followed (ČSN 50526-3. the spot you can perform a complete check the voltage limiter by means insulation testing device such as for instance Megger MIT 1025 Fluke 1555. Especially after extreme weather conditions i. Minimum cross-connecting wire (Cu) mm2 , recommended cross section mm2 . can perform the installation.r. ALVL consists of MOV varistors, high-power thyristors and electronic components (differential delay element), which within about msec can activate both in-built high-power thyristors.2. The housing made silicone caoutchouc which has great resistance surface creepage currents and electric arc..: +420 491 618 571 info@acervoltage.com In Hradec Kralove 23. Based varistor polarity, the corresponding thyristor being activated and the current flowing through the activated varistor, now starts flow through the thyristor. Bratri Stefanu 1170 Hradec Kralove 500 03 Czech Republic tel. case of a failure due connection between live part of traction power supply system and the conductive part accidentally connected to the return circuit, the limiter protects against impermissible touch voltage becoming conductive and causing cut-off the current flow. The limiter designed way enabling transmitting high temperatures rising inside the equipment into the aluminium structure.2 class (bi-directional), VLD-O+F type, used primarily traction systems protect against electric shock when touching non-live metal parts of structures power supply systems. has hydrophobic properties and shows excellent resistance to weathering, contamination, light well as harsh treatment and mechanical damage.acervoltage. 3. Type Non-triggering voltage UW Nominal triggering voltage US ALVL DC ALVL 120 120 DC The Declaration Conformity the product available for download our website www. 4