Návod na instalaci omezovačů nízkého napětí ALVL

| Kategorie: Leták / Datasheet  | Tento dokument chci!

Vydal: ACER VOLTAGE s.r.o.

Strana 2 z 2







Poznámky redaktora
3. Based varistor polarity, the corresponding thyristor being activated and the current flowing through the activated varistor, now starts flow through the thyristor. Type Non-triggering voltage UW Nominal triggering voltage US ALVL DC ALVL 120 120 DC The Declaration Conformity the product available for download our website www.GENERALRULES FORLIMITERCONNECTION Only the authorized person with an appropriate certification according ČSN EN 50110-1 ed.acervoltage. Functional check ALVL Overload the ALVL limiters may lead to a fault one even both thyristors. During the process the standards must be followed (ČSN 50526-3. soon as the overvoltage condition ends, the thyristors cut off the current flow and the original condition restored.r.com . the spot you can perform a complete check the voltage limiter by means insulation testing device such as for instance Megger MIT 1025 Fluke 1555. case of a failure due connection between live part of traction power supply system and the conductive part accidentally connected to the return circuit, the limiter protects against impermissible touch voltage becoming conductive and causing cut-off the current flow.e.2 class (bi-directional), VLD-O+F type, used primarily traction systems protect against electric shock when touching non-live metal parts of structures power supply systems. can perform the installation.com www.acervoltage. Minimum cross-connecting wire (Cu) mm2 , recommended cross section mm2 . Recommended mounting position vertical bracket up..2. Bratri Stefanu 1170 Hradec Kralove 500 03 Czech Republic tel.. CHARACTERISTICS PRODUCT AND BASIC PROPERTIES If overvoltage occurs for longer period of time (milliseconds hours) the thyristors fire limit touch voltage value.com In Hradec Kralove 23. Especially after extreme weather conditions i. According 50122-1:2011 this type of limiter recommended mainly for the connection between the protected part and return circuit the overhead line zones (or pantograph zones) that may contact with the conductors damaged current collector, then the support structures of pylons which can become live due an insulation failure.: +420 491 618 571 info@acervoltage. Also check they are not excessively covered by dirt. FIELD APPLICATION AND PLACE ALVL and ALVL 120 low voltage limiters, recoverable VLD 2. has hydrophobic properties and shows excellent resistance to weathering, contamination, light well as harsh treatment and mechanical damage. The limiter designed way enabling transmitting high temperatures rising inside the equipment into the aluminium structure. They are used effectively protect persons, who may come into contact with these parts during lightning strikes case a defect the traction power line. The ALVL limiters are maintenance free, have high insulation resistance value (kW) and high protection capability. ALVL consists of MOV varistors, high-power thyristors and electronic components (differential delay element), which within about msec can activate both in-built high-power thyristors. The limiter has installed directly between the elements the protected structures (using two bolts M12) the event its activation has occurred desired equipotential between them. Such activation corresponds the voltage drop across the varistor.. The connecting conductors can made with a circular section. is therefore recommended test the ALVL in regular intervals. 4.o. storms.Instructions for installing of low-voltage limiters ALVL 60 ALVL 120 1. Check the limiters are not mechanically damaged regular intervals. During assembly necessary respect the principles occupational safety and health. Before you can perform the control measurement you must disconnect the low voltage limiter.). 2. The housing made silicone caoutchouc which has great resistance surface creepage currents and electric arc.2022 ALVL* ACER VOLTAGE s