The Lighting Handbook ZG

| Kategorie: Firemní tiskovina  | Tento dokument chci!

Vydal: ZG Lighting Czech Republic s.r.o

Strana 17 z 244







Poznámky redaktora
fact, these levels ought to be sig­ nificantly exceeded and should at least 175 walls. Modelling the ratio between cylindrical and horizontal illuminance specific point and should between 0.6.3 and 0. The 12464 standard therefore requires illuminance level least lx or lx* ceilings and least or 75 lx* walls.17 The Lighting Handbook Illuminance levels ceilings and walls Spatial illumination Unlit ceilings and walls create unpleasant room impression. ĒZ . Bright surfaces, however, pleasantly enhance the room climate. * offices, class rooms, hospitals In order enhance people’s and objects’ recognisability room, basic requirements are placed cylindrical illuminance and modelling. Hence, should high 150 in rooms used for communication