Katalog Distribuce energie

| Kategorie: Katalog  | Tento dokument chci!

Vydal: HAGER ELECTRO s.r.o.

Strana 1040 z 1142

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.







Poznámky redaktora
transmitting power: mW - Receiver category 2 - Range: 100 free field BLE LED status Operation off Bluetooth® disabled Blue Bluetooth® enabled Blue Bluetooth® assembled and connected Figure LED operation and status CONFIGURATION APPLICATION To set the clock, use the application and perform the installation described below. transmitting power: mW - Range: free field - Version: 4. 2. • Produkt nesmí být konfiguračním režimu „quicklink“. • 200 400 program steps (depending version) On, Off, pulses . The keys EGN100 C1/FCT (key and LED) used for: • output control; • programming the RF module operating mode, • Bluetooth® reset. • Programming application via Bluetooth® technology: - automatic daylight savings time change; - astronomical mode; - programming day group days; - 100 program steps On, Off, pulses .Pair your mobile terminal and your clock via the Bluetooth® application. Zobrazení domovské obrazovky. Each time the BLE key pressed the function is enabled disabled. 1 Override input or exception 2 Brightness sensor Figure EGN200 connection diagram outputs) 1 Override input exception 2 Brightness sensor Image EGN400 connection diagram outputs) Technical specifications Electrical specifications • Supply voltage: 230 +10/-15% and 240 6% Hager Mood The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. Při každém stisknutí tlačítka BLE s) je funkce povolena nebo zakázána.Check that Bluetooth® is enabled (see Initial set-up / BLUETOOTH). and any use such marks Hager under license. and any use such marks Hager under license. • Twilight switch function via EEN002 EEN003 wired brightness sensor. 2. • Before connecting the brightness sensor, or before carrying out any operations on it, cut the 230 power supply the clock.2 • Mobile/PC terminal configuration - iOS version equal greater than 8 - Android version equal greater than 5. breaking capacity: AC1 10A 230 V~ • Incandescent light bulbs: - Power relay with normally open contact/2300 W - Power relay with normally closed contact/1500 W • Halogen lamps: 230 2300 W • Fluorescent tubes, compensated (max. 1. • Astronomical mode. 5.5 mm2 • Screw recess: PH1 Initial set-up BLUETOOTH The product must not “Quicklink” configuration mode. Popis hodin EGN100 C1 FCT (tlačítko LED) používané pro: • řízení výstupu; • programování provozního režimu RF bezdrátového modulu, • Resetování Bluetooth® . this, follow the application instructions configure the clock. • Programming application via Bluetooth® or local programming (except annual). μF): - Power relay with normally open contact/400 W - Power relay with normally closed contact/300 W • Fluorescent tubes, uncompensated, series compensated: 1000 W • Compact fluorescent lamps and LED lamps: • Insulation class: 2 • Action type: 2B • Software class: Class A • Ball test T°: °C • Upstream protection: circuit breaker • Stated voltage and current for EMC emissions testing: 230 0. • Permanent overrides Off. Ruční zapnutí výstupu (příkaz dispozici, pouze pokud má produkt tlačítko FCT) “ON výjimka pro zapnutí výstupu ohledem aktuální program; návrat automatického režimu nastane dalším kroku programu Funkce vynuceného potlačení zapnutí výstupu, když je stavu ZAP. this, Connection diagram • Device installed only qualified electrician according the standards applicable the country. • Max. 5.1 - Windows version equal greater than 10 - Bluetooth® : version equal greater than 4. Image Presentation keys Main features • Product delivered with updated time and day (Paris). • Automatic daylight savings time change. Stavová provozní LED • Bluetooth® musí být odpojeno. Programming performed with mobile terminal via Bluetooth® technology using the configuration application (iOS and Android) available free download. wechselt wieder den Modus Auto, wenn wieder Spannung anliegt oder eine Taste betätigt wird. transmitting power: mW - Range: free field - Version: 4. The connection EEN002 EEN003 twilight sensor (optional) makes possible switch the loads according brightness. • Temporary overrides Off.2 mm2 • Flexible 0. Novinka Ovládací zařízení 1039 Digitální spínací hodiny 6LE007020B n erhalten Sie, obilen Endgerät Code scannen. • Programming day group days. tr - Receive - Range: • Insulatio • Action ty • Software • Ball test • Upstream • Stated vo 230 / • Protectio • Impact re Battery • Power re • Non-repl Case • EGN200 • EGN400 • DIN rail m EN 6071 Environm • Operatin • Storage • Relative • Pollution Connectio • Rigid 0. Other trademarks and trade names are those their respective owners Additional information available by scanning the displayed code with your mobile terminal. Pouze zrušením vynuceného potlačení umožňuje opětovné řízení programem.4 2. Display and keys Screensaver ▲ ▼ Date Bluetooth® enabled Time Channel status A, B, C, D (depending on version) Functiona • Program on the m • Min. • Temporary overrides Off.Check that Bluetooth® is enabled (seeSettings / BLUETOOTH chapter). The keys EGN100 C1/FCT (key and LED) used for: • output control; • programming the RF module operating mode, • Bluetooth® reset.Pair your Bluetoot 5. BLE/CFG (key and LED) used for: • Bluetooth® activation and deactivation (BLE), • module configuration; • Resetting parameters and RF modules. The EGN200 and EGN400 switches are also compatible with the Hager Quicklink radio product line. 4. Settings via the configuration application: Settings for the use your clock are available via the application settings of: • date and time; • astronomical clock; • wired input; • daylight savings time change; • twilight sensor.Directly access the application’s download link by scanning the code printed the instructions with mobile terminal. • Exceptions (temporary, permanent delayed) can be activated remotely using push button.Downloa 3.5 A • Protection class: IP20 (case), IP30 (case under faceplate) • Impact resistance: IK04 Battery • Power reserve: years • Non-replaceable and non-rechargeable Case • Dimensions: module • DIN rail mounted independent product according to EN 60715 Environment • Operating +45 °C • Storage -25 +70 °C • Relative humidity: °C • Pollution category 2 Connection with screw terminals • Rigid 0. Connection diagram L N 1 5 3 7 2 6 4 8 1 Override input or exception 2 Brightness sensor Figure EGN100 connection diagram output) Technical specifications Electrical specifications • Supply voltage: 230 +10/-15% and 240 6% • Network frequency: 50/60 Hz • Consumption: 170 mW • Output: non-insulated changeover contact with a voltage measurement for zero-crossing switching. • 200 400 program steps (depending version) On, Off, pulses . μF): - Power relay with normally open contact/400 W - Power relay with normally closed contact/300 W • Fluorescent tubes, uncompensated, series compensated: 1000 W • Compact fluorescent lamps and LED lamps: - Power relay with normally open contact/400 W - Power relay with normally closed contact/300 W • Min. • Programming day group days.4 2. breaking capacity: AC1 100 230 V~ • Rated shock voltage: kV • Maximum switching speed full load: switching cycles/minute Functional features • Programming capacity: 100 steps • Min. • Backlit screen. 5. Nastavení možnosti ručního ovládání Návrat na domovskou obrazovku Zobrazení stavu výstup: • stav výstupu ZAP. (černé pozadí) • stav výstupu VYP. • Bar graph display the daily profile for 4 channels (depending version).Program your product via the application.Download and install the configuration application. • Schutzklasse (Gehäuse): IK03 • Schutzklasse (Gehäuse hinter Frontplatte): / IK03 • Aktions-Typ: 2B • Verschmutzungsgrad: 2 • Software-Struktur: Klasse A Umgebung • Betriebstemperatur: -5°C bis +45°C • Lagertemperatur: -25°C bis +70°C • Relative Feuchtigkeit: bei 20°C Anschluss über Käfigklemmen • Flexibler Querschnitt: bis mm2 • Starrer Querschnitt: 1,5 bis mm2 Anschlussplan estellten orhandenen Programms rzeit, Auswahl des eitumstellung- Einstellung Auswahl der gen oder blinkenden rherigen ber Menü tigung, en Modus Bild Anschlussplan EGN103 Ausgang) und aktuellem umstellung Programms gesgruppierung n oder Off ff blinkt) z is/ 2300 W 1500 W W n (max. 3. • Automatic daylight savings time change.1 - Windows version equal greater than 10 - Bluetooth® : version equal greater than 4. Ausschaltvermögen: AC1: 100 230 V~ • maximales Schalttempo bei voller Leistung: 6 Schaltzyklen/Minute • Bemessungsstoßspannung: kV • Vorgeschaltete Schutzvorrichtung: Unterbrecher 16 A • Abmessungen: Module (17,5 2) • Max. The integrated astronomical clock can set switch loads according to sunset and sunrise times. • Bluetooth® radio frequency: 2. Změna kanálu B, C nebo D (v závislosti na verzi) Čas Konfigurace quicklink Jas Aktuálně zobrazený kanál Graf denního profilu Výběr dnů (kurzor) Popis displeje tlačítek EGN200 EGN400 EGN400 6LE005561D EGN200, EGN400 z Multi-function Time Switch 2 Channel Bluetooth® 4 Channel Bluetooth® Product Presentation The EGN200 and EGN400 time switches are clocks with weekly and annual electronic programming that automatically control different loads.Directly access the download link the application by scanning the code printed the clock and the instructions with mobile terminal. 4.Technické změny vyhrazeny. time between steps: minute • Precision operation: ±0. 2. The connection EEN002 EEN003 twilight sensor (optional) makes possible switch the loads according brightness. time • Precision • The prod after m It returns when k • Bluetoot - Max.Download and install the configuration application. Programming performed with mobile terminal via Bluetooth® technology using the configuration application (iOS and Android) available free download. 3. • Programmable when off via screen only (with limited functionality). The EGN100 switch also compatible with the Hager Quicklink radio product line.Directly a scanning instructio 2. • Not suitable for controlling SELV loads.2 • Mobile/PC terminal configuration - iOS version equal greater than 8 - Android version equal greater than 5. time between steps: minute • Precision operation: ±0.483 GHz - Max.Check that Bluetooth® is enabled (see Initial set-up / BLUETOOTH). • Permanent overrides Off. Main features • Product delivered with updated time and day (Paris). this, follow the application instructions configure the clock.Pair your mobile terminal and your clock via the Bluetooth® application. breaking capacity: AC1 10A 230 V~ • Incandescent light bulbs: - Power relay with normally open contact/2300 W - Power relay with normally closed contact/1500 W • Halogen lamps: 230 2300 W • Fluorescent tubes, compensated (max. The integrated astronomical clock can set to switch loads according sunset and sunrise times. Examples applications: street lighting, neon signs, shop windows, monuments, facades etc. It returns auto mode when power restored or when key pressed.Directly access the application’s download link by scanning the code printed the instructions with mobile terminal. Press the o Once the s automatic Manua From the s Connection diagram • Device installed only qualified electrician according the standards applicable the country.Program your product via the application.25 s/day • Bluetooth® radio frequency: 2. Examples applications: street lighting, neon signs, shop windows, monuments, facades etc.2 2. 3. Pokud aktivní vynuceného potlačení, žádný jiný příkaz nižší prioritou nemá vliv změnu stavu. Main features • Product delivered with updated time and day (Paris). μF): Schéma zapojení EGK103 6LE005554C 1 The EGN100 switch also compatible with the Hager Quicklink radio product line. BLE/CFG (key and LED) used for: • Bluetooth® activation and deactivation (BLE), • module configuration; • Resetting parameters and RF Before connecting the cell, before carrying out any operations it, cut the 230 power supply the clock.2 2. 1.Check th BLUETO 4. 1 Override input or exception 2 Brightness sensor Figure EGN200 connection diagram outputs) Hager Mood The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. 6LE005554C • Device installed only qualified electrician according the installation standards applicable the country. • Exceptions (temporary, permanent delayed) can be activated remotely using push button. • Max. BLE Stavové provozní LED off Bluetooth® vypnuto Bluetooth® povoleno Bluetooth® připojeno Upozornění: pro nastavení Bluetooth® nesmí být produkt v konfiguračním režimu „Quicklink“. Programming mobile terminal recommended via Bluetooth® technology using the configuration application (iOS and Android) available free download. onique > Schaltleistung Schließer-Relais/ 400 W > Schaltleistung Öffner-Relais/ 300 W - Nicht- oder serienkompensierte Leuchtstofflampen: 1000 W - Kompaktleuchtstofflampen und LED-Lampen: > Schaltleistung Schließer-Relais/ 400 W > Schaltleistung Öffner-Relais/ 300 W • Min.2 • Quicklink radio frequency: 868 870 MHz - Max.2 • Quicklink radio frequency: 868 870 MHz - Max. • Exceptions (temporary, permanent delayed) can be activated remotely using push button. • Programming application via Bluetooth® or local programming (except annual). • Before connecting the brightness sensor, or before carrying out any operations on it, cut the 230 power supply the clock. BLE CFG (tlačítko LED) používané pro: • Aktivaci deaktivaci Bluetooth® (BLE), • Konfigurace bezdrátového modulu; • Resetování parametrů a bezdrátových modulů. To program and set the clock with mobile terminal, the Bluetooth® function must activated.2 mm2 • Flexible 0. 4. • Temporary overrides Off. The EGN200 and EGN400 switches are also compatible with the Hager Quicklink radio product line. The integrated astronomical clock can set switch loads according to sunset and sunrise times. • Permanent overrides Off. • Programmable when off via screen only (with limited functionality).Program follow the With the lo During initi • language • year, mo • hour and • daylight Press keys display. Höhe: 2000 m • Wärmeklasse: 2 • Temperatur für den Kugelversuch: 75°C • Strom und Spannung gemeldet für die EMV- Störabstrahlungsmessung: 230 0,5 A • Steuervorrichtung als Aufbauversion auf DIN- Schiene gemäß 60715 Funktionsmerkmale • Programmierkapazität: Schritte • Mindestzeit zwischen zwei Schritten: Minute • Ganggenauigkeit: ±1,5 s/24 h • Gangreserve Lithiumbatterie, insgesamt Jahre bei Stromausfall • Das Produkt schaltet den Standby-Modus (ausgeschaltetes Display), wenn mindestens eine Minute keine Spannung anliegt. The connection EEN002 EEN003 twilight sensor (optional) makes possible switch the loads according brightness. z Multi-function Time Switch 1 Channel Bluetooth® Product Presentation The EGN100 time switch clock with weekly and annual electronic programming that automatically controls different loads. Programming mobile terminal recommended via Bluetooth® technology using the configuration application (iOS and Android) available free download. transmitting power: mW - Receiver category 2 - Range: 100 free field • Insulation class: 2 • Action type: 2B • Software class: Class A • Ball test T°: °C • Upstream protection: circuit breaker • Stated voltage and current for EMC emissions testing: 230 0. The connection EEN002 EEN003 twilight sensor (optional) makes possible switch the loads according brightness.5 mm2 • Screw recess: PH1 Initial set-up With the configuration application If the application used configure the clock, install as described below. tr - Range: - Version • Mobile/P - iOS ver - Android - Window - Bluetoo • Quicklink - Max. 1 vstup pro tlačítko vynuceného potlačení 2 vstup pro soumrakové čidlo 1 vstup pro tlačítko pro vynuceného potlačení 2 vstup pro soumrakové čidlo EGN200 6LE005561D EGN200, EGN400 z Multi-function Time Switch 2 Channel Bluetooth® 4 Channel Bluetooth® Product Presentation The EGN200 and EGN400 time switches are clocks with weekly and annual electronic programming that automatically control different loads. • Backlit screen.Pair your mobile terminal and your clock via the Bluetooth® application.Download and install the configuration application. EGN100 1 vstup pro tlačítko pro vynuceného potlačení 2 vstup pro soumrakové čidlo EGN100 . • Twilight switch function via EEN002 EEN003 wired brightness sensor.2 • Flexible 0 • Screw re Initial s With the c If the applic described 1.5 A • Protection class: IP20 (case), IP30 (case under faceplate) • Impact resistance: IK04 Battery • Power reserve: years with action • Non-replaceable and non-rechargeable Case • EGN200 dimensions: modules • EGN400 dimensions: modules • DIN rail mounted independent product according to EN 60715 Environment • Operating +45 °C • Storage -25 +70 °C • Relative humidity: 20°C • Pollution category 2 Connection with screw terminals • Rigid 0. Examples applications: street lighting, neon signs, shop windows, monuments, facades etc.Program your product via the application. Pokud aktivní vynucené potlačení, žádný jiný příkaz nižší prioritou nemá vliv změnu stavu. Settings via the configuration application: Settings for the use your clock are available via the application settings of: • date and time; Hager Mood Additional information available by scanning the displayed code with your mobile terminal. Ruční zapnutí výstupu (příkaz dispozici, pouze pokud má produkt tlačítko FCT) Pro programování nastavení hodin pomocí mobilního zařízení musí být aktivována funkce Bluetooth® . 3 7 2 6 4 8 1 Override input or exception 2 Brightness sensor Figure EGN100 connection diagram output) Technical specifications Electrical specifications • Supply voltage: 230 +10/-15% and 240 6% • Network frequency: 50/60 Hz • Consumption: 170 mW • Output: non-insulated changeover contact with a voltage measurement for zero-crossing switching. Pouze zrušením vynuceného potlačení nebo manuálním sepnutím přes ovládací panel umožňuje opětovné řízení programem. Při každém krátkém stisknutí tlačítka stav výstupu změní podle následujícího cyklu: C1 Stavové provozní LED off OFF výjimka pro vypnutí výstupu ohledem aktuální program; návrat automatického režimu nastane dalším kroku programu Funkce vynuceného potlačení vypnutí výstupu, když je stavu VYP.483 GHz - Max. • Astronomical mode.25 s/day • The product switches the standby state (display off) after minute voltage inactivity. (bílé pozadí) Zobrazení možností Změna kanálu A, nebo D Spořič obrazovky Datum Čas Stav kanálu A, D (v závislosti na verzi) Bluetooth® povoleno Jedním stiskem zapnete podsvícení, druhým zobrazíte domovskou obrazovku. Other trademarks and trade names are those their respective owners Additional information available by scanning the displayed code with your mobile terminal. 1. • Bar graph display the daily profile for 4 channels (depending version). • Twilight switch function via EEN002 EEN003 Functional features • Programming capacity: 200 400 steps depending on the model • Min. BLE LED status Operation off Bluetooth® disabled Blue Bluetooth® enabled Blue Bluetooth® assembled and connected Figure LED operation and status CONFIGURATION APPLICATION To set the clock, use the application and perform the installation described below