JUNG HOME Puck switch actuator 2-gang with binary inputs
24 25
82410103 15.
Invert switching
output
Off, On
Default setting: Off
Inverts the switching output from con-
tact function (on switching output
closed) contact function (On =
switching output open).Parameters Setting options, default
setting
Explanation
Run-on time
(load)
0 (off) .
The load can switched off early during
a running run-on time only the "Manual
switch-off during run-on time" parameter
is set "On" disabling function (con-
tinuous OFF) started.
Minimum
switching repeat
time
100 ..05..
Manual switch-
off during run-
on time
Off, On
Default setting: On
If this parameter set "On", pos-
sible switch off the load manually dur-
ing current "run-on time (load)".. 240 min
Default setting: Off
Ensures that the load switched off after
the set run-on time expires instead re-
maining permanently switched after a
switch-on command..
If movement detected linked
JUNG HOME sensor cover during the
run-on time the operating cover is
switched again operating exten-
sion linked JUNG HOME operating
cover, the run-on time restarted and the
light remains on. Neither the switching
commands from the JUNG HOME operat-
ing sensor covers nor the display the
switching statuses the app are taken
into account.
This parameter only inverts the behaviour
of the load output. s
Default setting: 100 ms
Limits the switching speed the device
by increasing the value, order pro-
tect the connected load, for example. The switching repeat
time starts after each switching operation.
Only when the set time has elapsed is
switching possible again. The last com-
mand during the blocking time ex-
ecuted after delay.2025
J0082410103
.
For automatic staircase lighting con-
trolled JUNG HOME operating and/or
sensor covers, this parameter should be
set "Off" prevent the light from being
switched off second person