Operation via the app remains possible. The effect the setting depends
on the function the linked load.
Operating lock lock, factory reset
lock, operating lock
Default setting: lock
Factory reset lock: prevents resetting on
the device and hence the removal from a
project and pairing again unauthorised
persons.
Operating lock: prevents normal opera-
tion the device and hence the load
from being controlled.2025
J0082410103
.Parameters Setting options,
Factory setting
Explanations
Input behaviour
E1
Input behaviour
E2
Rising edge: reaction,
switch dim /
move increase set-
point temperature stop,
switch off dim down /
move down reduce set-
point temperature stop,
switch over
Default setting: switch
over
Falling edge: reac-
tion, switch dim /
move stop in-
crease setpoint temper-
ature, switch off dim
down move down /
stop reduce setpoint
temperature, switch over
Default setting: reac-
tion
The input behaviour can configured for
a rising edge (voltage input switched
on) and for falling edge (voltage input
is switched off) independently one an-
other. The "no
reaction" option has the effect that the
linked device does not change its status if
the selected edge detected the bin-
ary input.
JUNG HOME Puck switch actuator 2-gang with binary inputs
21 25
82410103 15.05.
The operating lock cannot deactivated
on the device.
Load control settings Lj
Settings for automatic functions ǐ
Parameters Setting options,
Factory setting
Explanations
Time programs Load status, time and
weekdays
The load status can changed at
defined times (weekdays and time). After the mains voltage returns,
the factory reset lock deactivated for
two minutes. This lock can be
used, for example, restrict manual ac-
cess temporarily