HELUKABEL: Katalog kabelů a vodičů 2018 (EN)

| Kategorie: Katalog  |

Vydal: Helukabel CZ s.r.o.

Strana 550 z 1153

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
O type Part no. s) +250°C Highest permissible voltage Ⴠ Cores stranded concentric layers Direct current systems 1,8 kV Ⴠ Outer sheath PVC compound type DMV6/DMP2 to 603 S1 Ⴠ Nominal voltage U0/U 0,6/1 Alternating current systems • Single-phase systems both outer conductors insulated 1,4 kV • Single-phase systems one outer conductor earthed 0,7 kV Ⴠ Test voltage kV Max.2 Ⴠ Ⴠ Power and control cable to DIN VDE 0276 part 603, HD 603 and IEC 60502 The materials used manufacture are cadmium-free and contain silicone and free from substances harmful to the wetting properties lacquers Ⴠ Temperature range flexing -5°C +50°C fixed installation -40°C +70°C Tests Ⴠ Core insulation cross-linked polyethylene (XLPE) compound type DIX3 to 603 S1 Ⴠ self-extinguishing and flame retardant acc. mm² - 6 32862 - 6 32850 242,0 154,0 11,5 re 1 16 - 4 32863 - 4 32851 362,0 240,0 12,5 rm 1 25 - 2 32864 - 2 32852 470,0 336,0 13,5 rm 1 35 - 1 32865 - 1 32853 620,0 480,0 15,5 rm 1 50 - 2/0 32866 - 2/0 32854 805,0 672,0 17,0 rm 1 70 - 3/0 32867 - 3/0 32855 1108,0 912,0 19,0 rm 1 95 - 4/0 32868 - 4/0 32856 1360,0 1152,0 20,5 rm 1 120 - 300 kcmil 32869 - 300 kcmil 32857 1670,0 1440,0 23,0 rm 1 150 - 350 kcmil 32870 - 350 kcmil 32858 2050,0 1776,0 25,5 rm 1 185 - 500 kcmil 32871 - 500 kcmil 32859 2635,0 2304,0 28,5 rm 1 240 - 600 kcmil 32872 - 600 kcmil 32860 3200,0 2880,0 30,0 rm 1 300 - 750 kcmil 32873 - 750 kcmil 32861 4150,0 3840,0 34,0 rm 1 400 - 6 32884 - 6 32874 1042,0 614,0 21,5 rm 4 16 - 4 32885 - 4 32875 1640,0 960,0 26,0 rm 4 25 - 2 32886 - 2 32876 1760,0 1344,0 27,5 rm 4 35 - 1 32887 - 1 32877 2350,0 1920,0 30,0 sm 4 50 - 2/0 32888 - 2/0 32878 3100,0 2688,0 34,0 sm 4 70 - 3/0 32889 - 3/0 32879 4250,0 3648,0 39,0 sm 4 95 - 4/0 32890 - 4/0 32880 5300,0 4608,0 42,5 sm 4 120 - 300 kcmil 32891 - 300 kcmil 32881 6400,0 5760,0 47,5 sm 4 150 - 350 kcmil 32892 - 350 kcmil 32882 8500,0 7104,0 52,0 sm 4 185 - 500 kcmil 32893 - 500 kcmil 32883 11000,0 9216,0 58,0 sm 4 240 Dimensions and specifications may changed without prior notice. permissible tensile stress with cable grip comductor 50 N/mm² Ⴠ Sheath colour black Ⴠ Three-phase systems 1,2 kV Ⴠ Minimum bending radius single-core 15x cable Ø multi-core 12x cable Note Ⴠ round conductor, single-wire rm round conductor, multi-wire sm sectional conductor, multi-wire Ⴠ J-version with GN-YE conductor O-version without GN-YE conductor Ⴠ AWG sizes are approximate equivalent values. The actual cross-section mm². J type Part no. mm No.cores x cross-sec.2, single-wire or multi-wire, 6360 cl.1 cl.1 cl. Respecting the permissible operating temperature the conductor +90°C permits higher current carrying capacity than PVC insulated power distribution cables. (RQ02) 548 Energy- and Power Cable Power Cables Power cables for energy supply . AWG-No. weight kg km Outer Ø app. km Cop.N2XYpower cable, 0,6/1kV, VDE approved, higher current carrying capacity Properties Cable structure Technical data Ⴠ Bare copper-conductor, to DIN VDE 0295 cl. Weight app. = The product conformed with the Low-Voltage Directive 2006/95/EC.2, IEC 60228 cl.1 cl. Application Power distribution cables for use underground, water, outdoors, concrete, indoors, cable ducts, for power stations, industrial applications and switching systems, well local networks mechanical damage expected. AWG-No. DIN VDE 0482-332-1-2, DIN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 Test method B) Ⴠ Permissible operating temperature at conductor +90°C Ⴠ Core identification to DIN VDE 0293-308, 0276 part 603 Ⴠ Permissible short circuit temperature (short circuit duration max