HELUKABEL: Katalog kabelů a vodičů 2018 (EN)

| Kategorie: Katalog  |

Vydal: Helukabel CZ s.r.o.

Strana 549 z 1153

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
permissible tensile stress with cable grip conductor 30 N/mm² Ⴠ Sheath colour black Ⴠ Three-phase systems 1,2 kV with concentric conductor and a cross-section from 240 mm² 3,6 kV Ⴠ Minimum bending radius 12x cable Ø Note Ⴠ round conductor, single-wire rm round conductor, multi-wire sm sectional conductor, multi-wire Ⴠ AWG sizes are approximate equivalent values. 8 603,0 87,0 88,0 20,2 re 10 3 10 36009 6 754,0 139,0 125,0 22,3 re 16 3 16 36010 4 1043,0 218,0 170,0 25,5 re 25 3 25 36011 4 1046,0 218,0 125,0 26,6 rm 16 3 25 36012 4 1101,0 218,0 170,0 26,6 rm 25 3 25 36013 2 1243,0 305,0 240,0 27,6 re 35 3 35 36014 2 1002,0 305,0 125,0 26,4 sm 16 3 35 36015 2 1107,0 305,0 240,0 26,4 sm 35 3 35 36016 1 1283,0 435,0 170,0 29,4 sm 25 3 50 36017 2/0 1633,0 609,0 240,0 32,6 sm 35 3 70 36018 2/0 1838,0 609,0 475,0 33,4 sm 70 3 70 36019 3/0 2136,0 827,0 340,0 38,1 sm 50 3 95 36020 3/0 2449,0 827,0 640,0 38,1 sm 95 3 95 36021 4/0 2517,0 1044,0 340,0 40,8 sm 50 3 120 36022 4/0 2612,0 1044,0 475,0 40,8 sm 70 3 120 36023 300 kcmil 3019,0 1305,0 475,0 44,9 sm 70 3 150 36024 300 kcmil 3517,0 1305,0 1000,0 45,5 sm 150 3 150 36025 350 kcmil 3741,0 1610,0 475,0 49,8 sm 70 3 185 36026 350 kcmil 3895,0 1610,0 640,0 49,8 sm 95 3 185 36027 500 kcmil 4539,0 2088,0 475,0 55,4 sm 70 3 240 36028 500 kcmil 4838,0 2088,0 800,0 55,8 sm 120 3 240 36029 500 kcmil 5611,0 2088,0 1665,0 56,0 sm 240 3 240 36030 6 801,0 186,0 125,0 23,9 re 16 4 16 32840 4 1243,0 290,0 125,0 28,9 re 16 4 25 32841 2 1282,0 406,0 125,0 30,3 re 16 4 35 32842 1 1689,0 580,0 170,0 34,8 sm 25 4 50 32843 2/0 2074,0 814,0 240,0 38,6 sm 35 4 70 32844 3/0 2779,0 1102,0 340,0 44,4 sm 50 4 95 32845 4/0 3365,0 1392,0 475,0 48,7 sm 70 4 120 32846 300 kcmil 3813,0 1740,0 475,0 53,3 sm 70 4 150 32847 350 kcmil 4877,0 2146,0 640,0 59,1 sm 95 4 185 32848 500 kcmil 6017,0 2784,0 800,0 66,0 sm 120 4 240 32849 Dimensions and specifications may changed without prior notice. This ensures optimal reliability. AWG-No. Wherever increased electrical and mechanical protection are required. The corrugated design (Ceander) the conc entric conductor permits any number cable junctions during assembly, without any conductors having cut. km Alu weight kg km Cop.cores x cross-sec. DIN VDE 0482-332-1-2, DIN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) Ⴠ Core identification DIN VDE 0293-308 Ⴠ Permissible operating temperature at conductor +70°C Cores stranded concentrically Ⴠ Permissible short circuit temperature (short circuit duration max. mm No.2 Ⴠ Ⴠ Power and control cable to DIN VDE 0276 part 603, HD 603 and IEC 60502 The materials used manufacture are cadmium-free and contain silicone and free from substances harmful to the wetting properties lacquers Ⴠ Temperature range flexing -5°C +50°C fixed installation -40°C +70°C Tests Ⴠ Core insulation PVC compound type DIV4 603 PVC self-extinguishing and flame retardant acc. Application Power distribution cables, preferably used for underground installation, primarily local networks, for industrial applications and switching systems, power stations. The concentric conductor (C) can used PEN conductor screen. The actual cross-section mm². Weight app.1 cl. 547 Energy- and Power Cable Power Cables Power cables for energy supply Q . mm² Part no. weight kg km Outer Ø app.1 cl.1 cl.NAYCWYpowercable,0,6/1kV,withconcentriccopperconductor,VDEapproved Properties Cable structure Technical data Ⴠ Aluminium-conductor, DIN VDE 0295 cl. s) +160°C Ⴠ Filling compound Highest permissible voltage Ⴠ Concentric conductor (Ceander), inner layer corrugated copper wires, outer layerwith copper tape Ⴠ Direct current systems 1,8 kV Ⴠ Nominal voltage U0/U 0,6/1 Alternating current systems • Single-phase systems both outer conductors insulated 1,4 kV • Single-phase systems one outer conductor earthed 0,7 kV Ⴠ Test voltage Outer sheath PVC compound type DMV5 603 S1 Ⴠ Max. Installation water, outdoors, concrete, indoors and cable ducts.2, single-wire multi-wire, BS 6360 cl.2, IEC 60228 cl. = The product conformed with the Low-Voltage Directive 2006/95/EC