HELUKABEL: Katalog kabelů a vodičů 2018 (EN)

| Kategorie: Katalog  |

Vydal: Helukabel CZ s.r.o.

Strana 551 z 1153

Vámi hledaný text obsahuje tato stránku dokumentu který není autorem určen k veřejnému šíření.

Jak získat tento dokument?






Poznámky redaktora
2, single-wire or multi-wire, 6360 cl. = The product conformed with the Low-Voltage Directive 2006/95/EC. Respecting the permissible operating temperature the conductor +90°C permits a higher current carrying capacity than PVC insulated power distribution cables. DIN VDE 0482-332-1-2, DIN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) Ⴠ Core identification DIN VDE 0293-308 Ⴠ Permissible operating temperature at conductor +90°C Ⴠ Cores stranded concentric layers Highest permissible voltage Ⴠ Filling compound Ⴠ Direct current systems 1,8 kV Ⴠ Permissible short circuit temperature (short circuit duration max. km Cop. mm² Part no.1 cl. Weight app. Application Power distribution cables for industrial applications and switching systems, power stations, residental connections and street lighting, well control cables for transmitting control pulses and measurements.1 cl. The concentric conductor (C) can used PEN-conductor or screen.cores x cross-sec.2 Ⴠ Ⴠ Power and control cable to DIN VDE 0276 part 603, HD 603 and IEC 60502, 7 cores and above DIN VDE 0276 part 627, 627 and IEC 60502 The materials used manufacture are cadmium-free and contain silicone and free from substances harmful to the wetting properties lacquers Tests Ⴠ Core insulation cross-linked polyethylene (XLPE) compound type DIX3 603 S1 Ⴠ Temperature range flexing -5°C +50°C fixed installation -40°C +70°C Ⴠ self-extinguishing and flame retardant acc. permissible tensile stress with cable grip conductor 50 N/mm² Ⴠ Three-phase systems 1,2 kV Note Ⴠ Minimum bending radius 12x cable round conductor, single-wire rm round conductor, multi-wire sm sectional conductor, multi-wire Ⴠ AWG sizes are approximate equivalent values. s) +250°C Ⴠ Concentric conductor, inner layer round bare copper wires, outer layer copper tape counter helix Ⴠ Alternating current systems • Single-phase systems both outer conductors insulated 1,4 kV • Single-phase systems one outer conductor earthed 0,7 kV Ⴠ Nominal voltage U0/U 0,6/1 Outer sheath PVC compound type DMV6 603 S1 Ⴠ Test voltage kV Ⴠ Sheath colour black Ⴠ Max.2, IEC 60228 cl. Wherever increased electrical and mechanical protection are required. weight kg km Outer Ø app. For installation in underground, water, outdoors, concrete and cable ducts. AWG-No. 16 205,0 53,0 13,0 re 1,5 2 1,5 33212 14 270,0 80,0 13,5 re 2,5 2 2,5 33213 12 360,0 123,0 15,5 re 4 2 4 33214 10 435,0 182,0 17,0 re 6 2 6 33215 8 590,0 312,0 19,5 re 10 2 10 33216 6 820,0 489,0 20,5 re 16 2 16 33217 16 225,0 66,0 13,5 re 1,5 3 1,5 33218 14 290,0 104,0 14,5 re 2,5 3 2,5 33219 12 400,0 161,0 16,5 re 4 3 4 33220 10 510,0 240,0 17,5 re 6 3 6 33221 8 850,0 408,0 20,0 re 10 3 10 33222 6 1080,0 643,0 23,0 re 16 3 16 33223 4 1295,0 902,0 25,1 rm 16 3 25 33224 4 1375,0 1003,0 25,0 rm 25 3 25 33225 2 1441,0 1190,0 25,1 sm 16 3 35 33226 2 1619,0 1402,0 25,4 sm 35 3 35 33227 1 1902,0 1723,0 27,3 sm 25 3 50 33228 1 2107,0 2000,0 27,7 sm 50 3 50 33229 2/0 2700,0 2410,0 32,2 sm 35 3 70 33230 2/0 3005,0 2796,0 32,7 sm 70 3 70 33231 3/0 3588,0 3296,0 35,3 sm 50 3 95 33232 3/0 4017,0 3791,0 35,8 sm 95 3 95 33233 4/0 4998,0 4786,0 38,9 sm 120 3 120 33234 4/0 4534,0 4236,0 38,9 sm 70 3 120 33235 300 kcmil 5937,0 5970,0 43,4 sm 120 3 150 33236 300 kcmil 5473,0 5100,0 43,4 sm 70 3 150 33237 350 kcmil 6831,0 6383,0 47,4 sm 95 3 185 33238 500 kcmil 8809,0 8242,0 52,5 sm 120 3 240 33239 Continuation Ⴇ 549 Energy- and Power Cable Power Cables Power cables for energy supply Q .1 cl. mm No. The actual cross-section mm².N2XCYpower cable, 0,6/1kV, VDE approved, higher current carrying capacity Properties Cable structure Technical data Ⴠ Bare copper-conductor, to DIN VDE 0295 cl